- Simulate for 5 seconds: The machine is started at nominal
speed, flux is build up in the machine.
 
- Continue the simulation for additional 5 seconds: Subsequently
a load ramp is applied.
 
- Compare by plotting versus Pmech:
 
| Current | 
I_sim | 
I_meas | 
| Speed | 
w_sim | 
w_meas | 
| Power factor | 
pf_sim | 
pf_meas | 
| Efficiency | 
eff_sim | 
eff_meas | 
Machine parameters are taken from a standard 18.5 kW 400 V 50 Hz
motor, simulation results are compared with measurements.
| Nominal stator current | 
32.85 | 
A | 
| Power factor | 
0.898 | 
 | 
| Speed | 
1462.5 | 
rpm | 
| Electrical input | 
20,443.95 | 
W | 
| Stator copper losses | 
770.13 | 
W | 
| Stator core losses | 
410.00 | 
W | 
| Rotor copper losses | 
481.60 | 
W | 
| Stray load losses | 
102.22 | 
W | 
| Friction losses | 
180.00 | 
W | 
| Mechanical output | 
18,500.00 | 
W | 
| Efficiency | 
90.49 | 
% | 
| Nominal torque | 
120.79 | 
Nm | 
| Stator resistance per phase | 
0.56 | 
Ω | 
| Temperature coefficient | 
copper | 
 | 
| Reference temperature | 
20 | 
°C | 
| Operation temperature | 
90 | 
°C | 
| Stator leakage reactance at 50 Hz | 
1.52 | 
Ω | 
| Main field reactance at 50 Hz | 
66.40 | 
Ω | 
| Rotor leakage reactance at 50 Hz | 
2.31 | 
Ω | 
| Rotor resistance per phase | 
0.42 | 
Ω | 
| Temperature coefficient | 
aluminium | 
 | 
| Reference temperature | 
20 | 
°C | 
| Operation temperature | 
90 | 
°C | 
See:
Anton Haumer, Christian Kral, Hansjörg Kapeller, Thomas Bäuml,
Johannes V. Gragger
The AdvancedMachines Library: Loss Models for Electric
Machines
Modelica 2009, 7th International Modelica Conference
Generated at 2020-06-05T07:38:22Z by OpenModelica 1.16.0~dev-420-gc007a39