The eddy current loss model with respect to fundamental wave effects is designed in accordance to FluxTubes.Basic.EddyCurrent.
![]()  | 
Due to the nature of eddy current losses, which can be
represented by symmetric conductors in an equivalent electric
circuit (Fig. 1), the respective number of phases 
 has to be taken into account. Assume that the 
 conductances of the equivalent circuit are 
, the conductance for the eddy current loss model is
determined by
where 
 is the number of turns of the symmetric electro magnetic
coupling.
For such an 
 phase system the relationship between the voltage and
current space phasors
and the magnetic flux and magnetic potential difference phasor
is
,
,
where 
 and 
 are the phase voltages and currents, respectively.
The dissipated loss power
can be determined for the space phasor relationship of the voltage and current space phasor.