The ideal transformer is a two-port circuit element; in case of
Boolean parameter considerMagnetization = false it is
characterized by the following equations:
i2 = -i1*n; v2 = v1/n;
where n is a real number called the turns ratio.
Due to this equations, also DC voltages and currents are
transformed - which is not the case for technical transformers.
In case of Boolean parameter considerMagnetization =
true it is characterized by the following equations:
im1 = i1 + i2/n "Magnetizing current w.r.t. primary side"; psim1= Lm1*im1 "Magnetic flux w.r.t. primary side"; v1 = der(psim1) "Primary voltage"; v2 = v1/n "Secondary voltage";
where Lm denotes the magnetizing inductance. Due to
this equations, the DC offset of secondary voltages and currents
decrement according to the time constant defined by the connected
circuit.
Taking primary L1sigma and secondary
L2ssigma leakage inductances into account, compared
with the basic
transformer the following parameter conversion can be applied
(which leads to identical results):
L1 = L1sigma + M*n "Primary inductance at secondary no-load"; L2 = L2sigma + M/n "Secondary inductance at primary no-load"; M = Lm1/n "Mutual inductance";
For the backward conversion, one has to decide about the partitioning of the leakage to primary and secondary side.