A single cell depleted to SOC = 0.1 is recharged
with a CC-CV charger. Charging current in CC mode is 5C which means
the battery is theoretically nearly fulled charged after
0.9*3600 s/5 = 648 s and the charger switches to CV
mode. Simulate for 1200 s and plot cell.cellBus.soc
versus time.