A single transient cell depleted to SOC = 0.1
is
recharged with a CC-CV charger. Charging current in CC mode is 5C
which means the battery is theoretically nearly fulled charged
after 0.9*3600 s/5 = 648 s
and the charger switches to
CV mode. Simulate for 1200 s and plot cell.cellBus.soc
versus time
.