.Modelica.Electrical.Machines.Examples.DCMachines.DCPM_Cooling

Information

Test example: Demonstrate cooling of a DCPM motor
The motor starts at no-load speed, then load pulses are applied.
The cooling circuit consists of armature's thermal capacitance, a thermal conductance between armature and core, core's thermal capacitance and a thermal conductance between core and coolant. The coolant flow circuit consists of inlet, volume flow, a pipe connected to the core and the outlet.
Please note:
  1. the total coolant's temperature rise is 10 K (over coolant inlet)
  2. the core's temperature rise is 27.5 K (over coolant's average temperature between inlet and outlet)
  3. the armature's temperature rise is 55 K (over coolant's average temperature between inlet and outlet)
Simulate for 25 seconds and plot (versus time): Therefore the armature temperature would reach nominal armature temperature at constant nominal load.
Default machine parameters are used, but:
Generated at 2020-06-05T21:39:08Z by OpenModelica 1.16.0~dev-442-g2e5bc9f