.Modelica.Fluid.Dissipation.PressureLoss.Orifice.dp_thickEdgedOverall_DP

Information

Calculation of pressure loss in thick edged orifices with sharp corners at overall flow regime for incompressible and single-phase fluid flow through an arbitrary shaped cross sectional area (square, circular, etc.) considering constant influence of surface roughness.

Generally this function is numerically best used for the incompressible case, where the mass flow rate (m_flow) is known (as state variable) in the used model and the corresponding pressure loss (DP) has to be calculated. On the other hand the function dp_thickEdgedOverall_MFLOW is numerically best used for the compressible case if the pressure loss (dp) is known (out of pressures as state variable) and the mass flow rate (M_FLOW) has to be calculated. See more information.

Interface

function dp_thickEdgedOverall_DP
  extends Modelica.Icons.Function;
  import FD = Modelica.Fluid.Dissipation.PressureLoss.Orifice;
  import SMOOTH = Modelica.Fluid.Dissipation.Utilities.Functions.General.Stepsmoother;
  input Modelica.Fluid.Dissipation.PressureLoss.Orifice.dp_thickEdgedOverall_IN_con IN_con "Input record for function dp_thickEdgedOverall_DP" annotation(
    Dialog(group = "Constant inputs"));
  input Modelica.Fluid.Dissipation.PressureLoss.Orifice.dp_thickEdgedOverall_IN_var IN_var "Input record for function dp_thickEdgedOverall_DP" annotation(
    Dialog(group = "Variable inputs"));
  input SI.MassFlowRate m_flow "Mass flow rate" annotation(
    Dialog(group = "Input"));
  output SI.Pressure DP "Output for function dp_thickEdgedOverall_DP";
end dp_thickEdgedOverall_DP;

Generated at 2020-06-05T21:39:08Z by OpenModelica 1.16.0~dev-442-g2e5bc9f