Calculation of the mean convective heat transfer coefficient
kc for a laminar fluid flow through an even gap at
different fluid flow and heat transfer situations.
Functions kc_evenGapLaminar and
kc_evenGapLaminar_KC
There are basically three differences:
- The function kc_evenGapLaminar is using
kc_evenGapLaminar_KC but offers additional output
variables like e.g. Reynolds number or Nusselt number and failure
status (an output of 1 means that the function is
not valid for the inputs).
- Generally the function kc_evenGapLaminar_KC is
numerically best used for the calculation of the mean convective
heat transfer coefficient kc at known mass flow
rate.
- You can perform an inverse calculation from
kc_evenGapLaminar_KC, where an unknown mass flow
rate is calculated out of a given mean convective heat transfer
coefficient kc
Restriction
- laminar regime (Reynolds number ≤ 2200)
- developed fluid flow
- heat transfer from one side of the gap
(target=Modelica.Fluid.Dissipation.Utilities.Types.kc_evenGap.DevOne)
- heat transfer from both sides of the gap
(target=Modelica.Fluid.Dissipation.Utilities.Types.kc_evenGap.DevBoth)
- undeveloped fluid flow
- heat transfer from one side of the gap
(target=Modelica.Fluid.Dissipation.Utilities.Types.kc_evenGap.UndevOne)
- Prandtl number 0.1 ≤ Pr ≤ 10
- heat transfer from both sides of the gap
(target=Modelica.Fluid.Dissipation.Utilities.Types.kc_evenGap.UndevBoth)
- Prandtl number 0.1 ≤ Pr ≤ 1000
Geometry
Calculation
The mean convective heat transfer coefficient
kc for an even gap is calculated through the
corresponding Nusselt number Nu_lam according to
[VDI 2002, p. Gb 7, eq. 43] :
Nu_lam = [(Nu_1)^3 + (Nu_2)^3 + (Nu_3)^3]^(1/3)
with the corresponding mean convective heat transfer coefficient
kc :
kc = Nu_lam * lambda / d_hyd
with
cp |
as specific heat capacity at constant pressure [J/(kg.K)], |
d_hyd = 2*s |
as hydraulic diameter of gap [m], |
eta |
as dynamic viscosity of fluid [Pa.s], |
h |
as height of cross sectional area in gap [m], |
kc |
as mean convective heat transfer coefficient [W/(m2.K)], |
lambda |
as heat conductivity of fluid [W/(m.K)], |
L |
as overflowed length of gap (normal to cross sectional area)
[m] , |
Nu_lam |
as mean Nusselt number [-], |
Pr = eta*cp/lambda |
as Prandtl number [-], |
rho |
as fluid density [kg/m3], |
s |
as distance between parallel plates of cross sectional area
[m], |
Re = rho*v*d_hyd/eta |
as Reynolds number [-], |
v |
as mean velocity in gap [m/s]. |
The summands for the mean Nusselt number Nu_lam
at a chosen fluid flow and heat transfer situation are calculated
as follows:
- developed fluid flow
- heat transfer from one side of the gap (target=1)
- Nu_1 = 4.861
- Nu_2 = 1.841*(Re*Pr*d_hyd/L)^(1/3)
- Nu_3 = 0
- heat transfer from both sides of the gap (target=2)
- Nu_1 = 7.541
- Nu_2 = 1.841*(Re*Pr*d_hyd/L)^(1/3)
- Nu_3 = 0
- undeveloped fluid flow
- heat transfer from one side of the gap (target=3)
- Nu_1 = 4.861
- Nu_2 = 1.841*(Re*Pr*d_hyd/L)^(1/3)
- Nu_3 = [2/(1+22*Pr)]^(1/6)*(Re*Pr*d_hyd/L)^(1/2)
- heat transfer from both sides of the gap (target=4)
- Nu_1 = 7.541
- Nu_2 = 1.841*(Re*Pr*d_hyd/L)^(1/3)
- Nu_3 = [2/(1+22*Pr)]^(1/6)*(Re*Pr*d_hyd/L)^(1/2)
Note that the fluid properties shall be calculated with an
arithmetic mean temperature out of the fluid flow temperatures at
the entrance and the exit of the gap.
Verification
The mean Nusselt number Nu_lam representing the
mean convective heat transfer coefficient kc in
dependence of the chosen fluid flow and heat transfer situations
(targets) is shown in the figure below.
References
- Bejan,A.:
- Heat transfer handbook. Wiley, 2003.
- VDI:
- VDI - Wärmeatlas: Berechnungsblätter für den
Wärmeübergang. Springer Verlag, 9th edition, 2002.