.Modelica.Fluid.Fittings.SimpleGenericOrifice

Information

This pressure drop component defines a simple, generic orifice, where the loss factor ζ is provided for one flow direction (e.g., from loss table of a book):

Δp = 0.5*ζ*ρ*v*|v|
   = 8*ζ/(π^2*D^4*ρ) * m_flow*|m_flow|

where

Since the pressure loss factor zeta is provided only for a mass flow from port_a to port_b, the pressure loss is not correct when the flow is reversing. If reversing flow only occurs in a short time interval, this is most likely uncritical. If significant reversing flow can appear, this component should not be used.


Generated at 2020-06-05T21:39:08Z by OpenModelica 1.16.0~dev-442-g2e5bc9f