Each phase
of an
phase winding has an effective number of turns,
and an respective winging angle
and a phase current
.
The total complex magnetic potential difference of the polyphase winding is determined by:
In this equation
is the positive symmetrical component of the currents.
The positive sequence of the voltages
induced in each winding is directly proportional to the complex
magnetic flux and the number of turns. This relationship can be
modeled by means of
.
Modelica.Magnetic.FundamentalWave.Components.SinglePhaseElectroMagneticConverter, Modelica.Magnetic.FundamentalWave.Components.PolyphaseElectroMagneticConverter, QuasiStaticAnalogElectroMagneticConverter