.Modelica.Electrical.Machines.Examples.DCMachines.DCEE_Start

Information

Test example: Electrically separate excited DC machine started with an armature voltage ramp
A voltage ramp is applied to the armature, causing the DC machine to start, and accelerating inertias.
At time tStep a load step is applied.
Simulate for 2 seconds and plot (versus time): Default machine parameters of model DC_ElectricalExcited are used.
Generated at 2020-06-05T07:38:22Z by OpenModelica 1.16.0~dev-420-gc007a39