Test example with multiphase components:
Star-connected voltage source feeds via two transformers (Dd0 and
Dy1) two diode bridge rectifiers with a single DC burden.
Using f=50 Hz, simulate for 0.1 seconds (5 periods) and compare
voltages and currents of source and DC burden, neglecting initial
transient.
Generated at 2020-06-05T07:38:22Z by OpenModelica 1.16.0~dev-420-gc007a39