The symmetry of the stator is assumed. For rotor asymmetries can
be taken into account by different resistances and stray
inductances in the d- and q-axis. The machine models take the
following loss effects into account:
- heat losses in the temperature dependent stator winding
resistances
- optional, when enabled: heat losses in the temperature
dependent damper cage resistances
- friction losses
- core losses (only eddy current losses, no hysteresis
losses)
- stray load losses
See also
SM_ElectricalExcited,
SM_PermanentMagnet,
Generated at 2020-06-05T07:38:22Z by OpenModelica 1.16.0~dev-420-gc007a39