Center tap rectifier with two pulses
This package includes single phase two pulse center tap rectifiers. The examples show uncontrolled and controlled rectifiers with constant and variable firing angle.
Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).
Name | Description |
---|---|
DiodeCenterTap2Pulse | Two pulse diode rectifier with center tap with resistive load |
ThyristorCenterTap2Pulse_R | Two pulse thyristor rectifier with center tap and resistive load |
ThyristorCenterTap2Pulse_RL | Two pulse thyristor rectifier with center tap and R-L load |
ThyristorCenterTap2Pulse_RLV | Two pulse thyristor rectifier with center tap and R-L load and voltage |
ThyristorCenterTap2Pulse_RLV_Characteristic | Characteristic of two pulse thyristor rectifier with center tap and R-L load and voltage |
Two pulse diode rectifier with center tap with resistive load
This example shows an uncontrolled two pulse center tap diode rectifier with resistive load.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from Modelica.Icons.Example (Icon for runnable examples).
Name | Description |
---|---|
Vrms | RMS supply voltage [V] |
f | Frequency [Hz] |
R | Load resistance [Ohm] |
Two pulse thyristor rectifier with center tap and resistive load
This example shows a controlled center tap two pulse rectifier with resistive load.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Name | Description |
---|---|
Vrms | RMS supply voltage [V] |
f | Frequency [Hz] |
constantFiringAngle | Firing angle [rad] |
R | Load resistance [Ohm] |
Two pulse thyristor rectifier with center tap and R-L load
This example shows a controlled center tap two pulse rectifier with R-L load.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Name | Description |
---|---|
Vrms | RMS supply voltage [V] |
f | Frequency [Hz] |
constantFiringAngle | Firing angle [rad] |
R | Load resistance [Ohm] |
L | Load resistance [H] |
Two pulse thyristor rectifier with center tap and R-L load and voltage
This example shows a controlled center tap two pulse rectifier with R-L load including DC voltage source. The additional DC voltage source in this example enables negative average load voltages.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Name | Description |
---|---|
Vrms | RMS supply voltage [V] |
f | Frequency [Hz] |
constantFiringAngle | Firing angle [rad] |
R | Load resistance [Ohm] |
L | Load resistance [H] |
VDC | DC load offset voltage [V] |
Characteristic of two pulse thyristor rectifier with center tap and R-L load and voltage
This example shows a controlled center tap two pulse rectifier with R-L load including DC voltage source. The additional DC voltage source in this example enables negative average load voltages.
Plot average voltage meanVoltage.v
versus firingAngle pulse2.firingAngle
to see control characteristic of this type of rectifier with R-L load including active voltage.
Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Name | Description |
---|---|
Vrms | RMS supply voltage [V] |
f | Frequency [Hz] |
R | Load resistance [Ohm] |
L | Load resistance [H] |
VDC | DC load offset voltage [V] |