Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse

2*m pulse rectifier with center tap

Information

This package includes multi phase center tap rectifiers. The number of phases, m, determines the number of pulses, 2*m. The examples show uncontrolled and controlled rectifiers with constant and variable firing angle.

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

Name Description
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.DiodeCenterTap2mPulse DiodeCenterTap2mPulse 2*m pulse diode center tap rectifier with resistive load
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_R ThyristorCenterTap2mPulse_R 2*m pulse thyristor center tap rectifier with resistive load
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_RL ThyristorCenterTap2mPulse_RL 2*m pulse thyristor rectifier with R-L load
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_RLV ThyristorCenterTap2mPulse_RLV 2*m pulse thyristor center tap rectifier with R-L load and voltage
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_RLV_Characteristic ThyristorCenterTap2mPulse_RLV_Characteristic Characteristic of 2*m pulse center tap thyristor rectifier with R-L load and voltage

Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.DiodeCenterTap2mPulse Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.DiodeCenterTap2mPulse

2*m pulse diode center tap rectifier with resistive load

Information

This example shows an uncontrolled 2*m pulse center tap diode rectifier with resistive load, where m is the number of phases.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of phases
VrmsRMS supply voltage [V]
fFrequency [Hz]
RLoad resistance [Ohm]

Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_R Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_R

2*m pulse thyristor center tap rectifier with resistive load

Information

This example shows a controlled 2*m pulse center tap rectifier with resistive load, where m is the number of phases.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from ExampleTemplates.ThyristorCenterTap2mPulse (Template of 2*m pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of phases
VrmsRMS supply voltage [V]
fFrequency [Hz]
constantFiringAngleFiring angle [rad]
RLoad resistance [Ohm]

Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_RL Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_RL

2*m pulse thyristor rectifier with R-L load

Information

This example shows a controlled 2*m pulse center tap rectifier with R-L load, where m is the number of phases.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from ExampleTemplates.ThyristorCenterTap2mPulse (Template of 2*m pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of phases
VrmsRMS supply voltage [V]
fFrequency [Hz]
constantFiringAngleFiring angle [rad]
RLoad resistance [Ohm]
LLoad resistance [H]

Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_RLV Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_RLV

2*m pulse thyristor center tap rectifier with R-L load and voltage

Information

This example shows a controlled 2*m pulse center tap rectifier with R-L load including DC voltage source, where m is the number of phases. The additional DC voltage source in this example enables negative average load voltages.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from ExampleTemplates.ThyristorCenterTap2mPulse (Template of 2*m pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of phases
VrmsRMS supply voltage [V]
fFrequency [Hz]
constantFiringAngleFiring angle [rad]
RLoad resistance [Ohm]
LLoad resistance [H]
VDCDC load offset voltage [V]

Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_RLV_Characteristic Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse.ThyristorCenterTap2mPulse_RLV_Characteristic

Characteristic of 2*m pulse center tap thyristor rectifier with R-L load and voltage

Information

This example shows a controlled 2*m pulse center tap rectifier with R-L load including DC voltage source, where m is the number of phases. The additional DC voltage source in this example enables negative average load voltages.

Plot average voltage meanVoltage.v versus firingAngle pulsem.firingAngle to see control characteristic of this type of rectifier with R-L load including active voltage.

Extends from ExampleTemplates.ThyristorCenterTap2mPulse (Template of 2*m pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of phases
VrmsRMS supply voltage [V]
fFrequency [Hz]
RLoad resistance [Ohm]
LLoad resistance [H]
VDCDC load offset voltage [V]
Automatically generated Thu Dec 19 17:19:58 2019.