Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors

Sensors to measure variables in magnetic networks

Information

For analysis of magnetic networks, only magnetic potential differences and magnetic flux are variables of interest. For that reason, a magnetic potential sensor is not provided.

Extends from Modelica.Icons.SensorsPackage (Icon for packages containing sensors).

Package Content

Name Description
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.ReferenceSensor ReferenceSensor Sensor of reference angle gamma
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.FrequencySensor FrequencySensor Frequency sensor
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialSensor MagneticPotentialSensor Potential sensor
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialDifferenceSensor MagneticPotentialDifferenceSensor Sensor to measure magnetic potential difference
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticFluxSensor MagneticFluxSensor Sensor to measure magnetic flux
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.Transient Transient Transient fundamental wave sensors

Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.ReferenceSensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.ReferenceSensor

Sensor of reference angle gamma

Information

This sensor determines the reference angle of the connected quasi static magnetic system. The integral of the angular frequency of the quasi static magnetic system is equal to the reference angle.

Extends from FluxTubes.Interfaces.AbsoluteSensor (Partial potential sensor).

Connectors

NameDescription
portQuasi-static magnetic port
yReference angle

Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.FrequencySensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.FrequencySensor

Frequency sensor

Information

This sensor can be used to measure the frequency of the reference system. The integral of the angular frequency of the quasi static magnetic system is equal to the reference angle.

Extends from FluxTubes.Interfaces.AbsoluteSensor (Partial potential sensor).

Connectors

NameDescription
portQuasi-static magnetic port
y 

Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialSensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialSensor

Potential sensor

Information

This sensor can be used to measure the complex magnetic potential V_m in a quasi static magnetic system.

Extends from FluxTubes.Interfaces.AbsoluteSensor (Partial potential sensor).

Connectors

NameDescription
portQuasi-static magnetic port
y 

Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialDifferenceSensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialDifferenceSensor

Sensor to measure magnetic potential difference

Information

This sensor can be used to measure the complex magnetic potential difference V_m in a quasi static magnetic system.

Extends from FluxTubes.Interfaces.RelativeSensor (Partial magnetic voltage or flux sensor).

Connectors

NameDescription
port_pPositive quasi-static magnetic port
port_nNegative quasi-static magnetic port
y 

Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticFluxSensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticFluxSensor

Sensor to measure magnetic flux

Information

This sensor can be used to measure the complex magnetic flux Phi of a quasi static magnetic system.

Extends from FluxTubes.Interfaces.RelativeSensor (Partial magnetic voltage or flux sensor).

Connectors

NameDescription
port_pPositive quasi-static magnetic port
port_nNegative quasi-static magnetic port
y 
Automatically generated Thu Dec 19 17:20:05 2019.