This package contains time-dependent and controlled multiphase voltage and current sources:
Extends from Modelica.Icons.SourcesPackage
(Icon for packages containing sources).
Name | Description |
---|---|
ConstantCurrent | Multiphase constant current source |
ConstantVoltage | Multiphase constant voltage source |
CosineCurrent | Multiphase cosine current source |
CosineVoltage | Multiphase cosine voltage source |
SignalCurrent | Multiphase signal current source |
SignalVoltage | Multiphase signal voltage source |
SineCurrent | Multiphase sine current source |
SineVoltage | Multiphase sine voltage source |
Contains m signal controlled voltage sources (Modelica.Electrical.Analog.Sources.SignalVoltage)
Type | Name | Default | Description |
---|---|---|---|
Integer | m | 3 | Number of phases |
Type | Name | Description |
---|---|---|
PositivePlug | plug_p |   |
NegativePlug | plug_n |   |
input RealInput | v[m] | Voltage between pin p and n (= p.v - n.v) as input signal |
Contains m constant voltage sources (Modelica.Electrical.Analog.Sources.ConstantVoltage)
Extends from Modelica.Electrical.MultiPhase.Interfaces.TwoPlug
(Component with one polyphase electrical port).
Type | Name | Default | Description |
---|---|---|---|
Integer | m | 3 | Number of phases |
Voltage | V[m] | Values of constant voltages |
Type | Name | Description |
---|---|---|
PositivePlug | plug_p | Positive polyphase electrical plug with m pins |
NegativePlug | plug_n | Negative polyphase electrical plug with m pins |
Contains m sine voltage sources (Modelica.Electrical.Analog.Sources.SineVoltage) with a default phase shift determined by symmetricOrientation.
Extends from Modelica.Electrical.MultiPhase.Interfaces.TwoPlug
(Component with one polyphase electrical port).
Type | Name | Default | Description |
---|---|---|---|
Integer | m | 3 | Number of phases |
Voltage | V[m] | Amplitudes of sine waves | |
Angle | phase[m] | -Modelica.Electrical.MultiPhase.Functions.symmetricOrientation(m) | Phases of sine waves |
Frequency | freqHz[m] | Frequencies of sine waves | |
Voltage | offset[m] | zeros(m) | Voltage offsets |
Time | startTime[m] | zeros(m) | Time offsets |
Type | Name | Description |
---|---|---|
PositivePlug | plug_p | Positive polyphase electrical plug with m pins |
NegativePlug | plug_n | Negative polyphase electrical plug with m pins |
Contains m cosine voltage sources (Modelica.Electrical.Analog.Sources.CosineVoltage) with a default phase shift determined by symmetricOrientation.
Extends from Modelica.Electrical.MultiPhase.Interfaces.TwoPlug
(Component with one polyphase electrical port).
Type | Name | Default | Description |
---|---|---|---|
Integer | m | 3 | Number of phases |
Voltage | V[m] | Amplitudes of cosine waves | |
Angle | phase[m] | -Modelica.Electrical.MultiPhase.Functions.symmetricOrientation(m) | Phases of cosine waves |
Frequency | freqHz[m] | Frequencies of cosine waves | |
Voltage | offset[m] | zeros(m) | Voltage offsets |
Time | startTime[m] | zeros(m) | Time offsets |
Type | Name | Description |
---|---|---|
PositivePlug | plug_p | Positive polyphase electrical plug with m pins |
NegativePlug | plug_n | Negative polyphase electrical plug with m pins |
Contains m signal controlled current sources (Modelica.Electrical.Analog.Sources.SignalCurrent)
Type | Name | Default | Description |
---|---|---|---|
Integer | m | 3 | Number of phases |
Type | Name | Description |
---|---|---|
PositivePlug | plug_p |   |
NegativePlug | plug_n |   |
input RealInput | i[m] | Current flowing from pin p to pin n as input signal |
Contains m constant current sources (Modelica.Electrical.Analog.Sources.ConstantCurrent)
Extends from Modelica.Electrical.MultiPhase.Interfaces.TwoPlug
(Component with one polyphase electrical port).
Type | Name | Default | Description |
---|---|---|---|
Integer | m | 3 | Number of phases |
Current | I[m] | Values of constant currents |
Type | Name | Description |
---|---|---|
PositivePlug | plug_p | Positive polyphase electrical plug with m pins |
NegativePlug | plug_n | Negative polyphase electrical plug with m pins |
Contains m sine current sources (Modelica.Electrical.Analog.Sources.SineCurrent) with a default phase shift determined by symmetricOrientation.
Extends from Modelica.Electrical.MultiPhase.Interfaces.TwoPlug
(Component with one polyphase electrical port).
Type | Name | Default | Description |
---|---|---|---|
Integer | m | 3 | Number of phases |
Current | I[m] | Amplitudes of sine waves | |
Angle | phase[m] | -Modelica.Electrical.MultiPhase.Functions.symmetricOrientation(m) | Phases of sine waves |
Frequency | freqHz[m] | Frequencies of sine waves | |
Current | offset[m] | zeros(m) | Current offsets |
Time | startTime[m] | zeros(m) | Time offsets |
Type | Name | Description |
---|---|---|
PositivePlug | plug_p | Positive polyphase electrical plug with m pins |
NegativePlug | plug_n | Negative polyphase electrical plug with m pins |
Contains m cosine current sources (Modelica.Electrical.Analog.Sources.CosineCurrent) with a default phase shift determined by symmetricOrientation.
Extends from Modelica.Electrical.MultiPhase.Interfaces.TwoPlug
(Component with one polyphase electrical port).
Type | Name | Default | Description |
---|---|---|---|
Integer | m | 3 | Number of phases |
Current | I[m] | Amplitudes of cosine waves | |
Angle | phase[m] | -Modelica.Electrical.MultiPhase.Functions.symmetricOrientation(m) | Phases of cosine waves |
Frequency | freqHz[m] | Frequencies of cosine waves | |
Current | offset[m] | zeros(m) | Current offsets |
Time | startTime[m] | zeros(m) | Time offsets |
Type | Name | Description |
---|---|---|
PositivePlug | plug_p | Positive polyphase electrical plug with m pins |
NegativePlug | plug_n | Negative polyphase electrical plug with m pins |
Generated 2018-12-12 12:10:17 EST by MapleSim.