This package includes single phase two pulse center tap rectifiers. The examples show uncontrolled and controlled rectifiers with constant and variable firing angle.
Extends from Modelica.Icons.ExamplesPackage
(Icon for packages containing runnable examples).
Name | Description |
---|---|
DiodeCenterTap2Pulse | Two pulse diode rectifier with center tap with resistive load |
ThyristorCenterTap2Pulse_R | Two pulse thyristor rectifier with center tap and resistive load |
ThyristorCenterTap2Pulse_RL | Two pulse thyristor rectifier with center tap and R-L load |
ThyristorCenterTap2Pulse_RLV | Two pulse thyristor rectifier with center tap and R-L load and voltage |
ThyristorCenterTap2Pulse_RLV_Characteristic | Characteristic of two pulse thyristor rectifier with center tap and R-L load and voltage |
This example shows an uncontrolled two pulse center tap diode rectifier with resistive load.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from Modelica.Icons.Example
(Icon for runnable examples).
Type | Name | Default | Description |
---|---|---|---|
Voltage | Vrms | 110 | RMS supply voltage |
Frequency | f | 50 | Frequency |
Resistance | R | 20 | Load resistance |
This example shows a controlled center tap two pulse rectifier with resistive load.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from Modelica.Electrical.PowerConverters.Examples.ACDC.ExampleTemplates.ThyristorCenterTap2Pulse
(Template of two pulse thyristor rectifier with center tap) and Modelica.Icons.Example
(Icon for runnable examples).
Type | Name | Default | Description |
---|---|---|---|
Voltage | Vrms | 110 | RMS supply voltage |
Frequency | f | 50 | Frequency |
Angle | constantFiringAngle | 0.005555555555556 * (30 * pi) | Firing angle |
Resistance | R | 20 | Load resistance |
This example shows a controlled center tap two pulse rectifier with R-L load.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from Modelica.Electrical.PowerConverters.Examples.ACDC.ExampleTemplates.ThyristorCenterTap2Pulse
(Template of two pulse thyristor rectifier with center tap) and Modelica.Icons.Example
(Icon for runnable examples).
Type | Name | Default | Description |
---|---|---|---|
Voltage | Vrms | 110 | RMS supply voltage |
Frequency | f | 50 | Frequency |
Angle | constantFiringAngle | 0.005555555555556 * (30 * pi) | Firing angle |
Resistance | R | 20 | Load resistance |
Inductance | L | 1 | Load resistance |
This example shows a controlled center tap two pulse rectifier with R-L load including DC voltage source. The additional DC voltage source in this example enables negative average load voltages.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from Modelica.Electrical.PowerConverters.Examples.ACDC.ExampleTemplates.ThyristorCenterTap2Pulse
(Template of two pulse thyristor rectifier with center tap) and Modelica.Icons.Example
(Icon for runnable examples).
Type | Name | Default | Description |
---|---|---|---|
Voltage | Vrms | 110 | RMS supply voltage |
Frequency | f | 50 | Frequency |
Angle | constantFiringAngle | 0.005555555555556 * (30 * pi) | Firing angle |
Resistance | R | 20 | Load resistance |
Inductance | L | 1 | Load resistance |
Voltage | VDC | -120 | DC load offset voltage |
This example shows a controlled center tap two pulse rectifier with R-L load including DC voltage source. The additional DC voltage source in this example enables negative average load voltages.
Plot average voltage meanVoltage.v
versus firingAngle pulse2.firingAngle
to see control characteristic of this type of rectifier with R-L load including active voltage.
Extends from Modelica.Electrical.PowerConverters.Examples.ACDC.ExampleTemplates.ThyristorCenterTap2Pulse
(Template of two pulse thyristor rectifier with center tap) and Modelica.Icons.Example
(Icon for runnable examples).
Type | Name | Default | Description |
---|---|---|---|
Voltage | Vrms | 110 | RMS supply voltage |
Frequency | f | 50 | Frequency |
Resistance | R | 20 | Load resistance |
Inductance | L | 1 | Load resistance |
Voltage | VDC | -120 | DC load offset voltage |
Generated 2018-12-12 12:10:18 EST by MapleSim.