For analysis of magnetic networks, only magnetic potential differences and magnetic flux are variables of interest. For that reason, a magnetic potential sensor is not provided.
Extends from Modelica.Icons.SensorsPackage
(Icon for packages containing sensors).
Name | Description |
---|---|
FrequencySensor | Frequency sensor |
MagneticFluxSensor | Sensor to measure magnetic flux |
MagneticPotentialDifferenceSensor | Sensor to measure magnetic potential difference |
MagneticPotentialSensor | Potential sensor |
ReferenceSensor | Sensor of reference angle gamma |
Transient … | Transient fundamental wave sensors |
This sensor determines the reference angle of the connected quasi static magnetic system. The integral of the angular frequency of the quasi static magnetic system is equal to the reference angle.
Extends from Modelica.Magnetic.QuasiStatic.FluxTubes.Interfaces.AbsoluteSensor
(Partial potential sensor).
Type | Name | Description |
---|---|---|
PositiveMagneticPort | port | Quasi-static magnetic port |
output RealOutput | y | Reference angle |
This sensor can be used to measure the frequency of the reference system. The integral of the angular frequency of the quasi static magnetic system is equal to the reference angle.
Extends from Modelica.Magnetic.QuasiStatic.FluxTubes.Interfaces.AbsoluteSensor
(Partial potential sensor).
Type | Name | Description |
---|---|---|
PositiveMagneticPort | port | Quasi-static magnetic port |
output RealOutput | y |   |
This sensor can be used to measure the complex magnetic potential V_m
in a quasi static magnetic system.
Extends from Modelica.Magnetic.QuasiStatic.FluxTubes.Interfaces.AbsoluteSensor
(Partial potential sensor).
Type | Name | Description |
---|---|---|
PositiveMagneticPort | port | Quasi-static magnetic port |
output ComplexOutput | y |   |
This sensor can be used to measure the complex magnetic potential difference V_m
in a quasi static magnetic system.
Extends from Modelica.Magnetic.QuasiStatic.FluxTubes.Interfaces.RelativeSensor
(Partial magnetic voltage or flux sensor).
Type | Name | Description |
---|---|---|
PositiveMagneticPort | port_p | Positive quasi-static magnetic port |
NegativeMagneticPort | port_n | Negative quasi-static magnetic port |
output ComplexOutput | y |   |
This sensor can be used to measure the complex magnetic flux Phi
of a quasi static magnetic system.
Extends from Modelica.Magnetic.QuasiStatic.FluxTubes.Interfaces.RelativeSensor
(Partial magnetic voltage or flux sensor).
Type | Name | Description |
---|---|---|
PositiveMagneticPort | port_p | Positive quasi-static magnetic port |
NegativeMagneticPort | port_n | Negative quasi-static magnetic port |
output ComplexOutput | y |   |
Generated 2018-12-12 12:11:07 EST by MapleSim.