SamplerIdeal sampling of continuous signals |
|
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Samples the continues input signal with a sampling rate defined via parameter samplePeriod.
| sampleTrigger |
Type: Boolean Description: True, if sample time instant |
|---|---|
| firstTrigger |
Type: Boolean Description: Rising edge signals first sample instant |
| u |
Type: RealInput Description: Connector of Real input signal |
|
|---|---|---|
| y |
Type: RealOutput Description: Connector of Real output signal |
|
Modelica.Blocks.Interfaces Discrete Single-Variable controller |
|
|
Modelica.Blocks.Interfaces Discrete Multi-Variable controller |