TriggeredTrapezoid

Triggered trapezoid generator

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

The block TriggeredTrapezoid has a Boolean input and a real output signal and requires the parameters amplitude, rising, falling and offset. The output signal y represents a trapezoidal signal dependent on the input signal u.

The behaviour is as follows: Assume the initial input to be false. In this case, the output will be offset. After a rising edge (i.e., the input changes from false to true), the output is rising during rising to the sum of offset and amplitude. In contrast, after a falling edge (i.e., the input changes from true to false), the output is falling during falling to a value of offset.

Note, that the case of edges before expiration of rising or falling is handled properly.

Parameters (4)

amplitude

Value: 1

Type: Real

Description: Amplitude of trapezoid

rising

Value: 0

Type: Time (s)

Description: Rising duration of trapezoid

falling

Value: rising

Type: Time (s)

Description: Falling duration of trapezoid

offset

Value: 0

Type: Real

Description: Offset of output signal

Connectors (2)

u

Type: BooleanInput

Description: Connector of Boolean input signal

y

Type: RealOutput

Description: Connector of Real output signal

Used in Examples (2)

PumpingSystem

Modelica.Fluid.Examples

Model of a pumping system for drinking water

BatchPlant_StandardWater

Modelica.Fluid.Examples.AST_BatchPlant