ControlledIdealOpeningSwitch

Controlled ideal electrical opener

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

The switching behaviour of the controlled ideal opening switch is controlled by the control pin: off = control.v > level
For further details, see partial model IdealSwitch.

Parameters (5)

useHeatPort

Value: false

Type: Boolean

Description: =true, if heatPort is enabled

T

Value: 293.15

Type: Temperature (K)

Description: Fixed device temperature if useHeatPort = false

Ron

Value: 1e-5

Type: Resistance (Ω)

Description: Closed switch resistance

Goff

Value: 1e-5

Type: Conductance (S)

Description: Opened switch conductance

level

Value: 0.5

Type: Voltage (V)

Description: Switch level

Connectors (4)

p

Type: PositivePin

Description: Positive electrical pin

n

Type: NegativePin

Description: Negative electrical pin

heatPort

Type: HeatPort_a

Description: Conditional heat port

control

Type: Pin

Description: Control pin: control.v > level switch open, otherwise p--n connected