StrayLoadParametersParameter record for stray load losses |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Parameter record for three-phase and DC stray load losses.
PRef |
Value: 0 Type: Power (W) Description: Reference stray load losses at IRef and wRef |
---|---|
IRef |
Value: Type: Current (A) Description: Reference RMS current that PRef refers to |
wRef |
Value: Type: AngularVelocity (rad/s) Description: Reference angular velocity that PRef refers to |
power_w |
Value: 1 Type: Real Description: Exponent of stray load loss torque w.r.t. angular velocity |
tauRef |
Value: if PRef <= 0 then 0 else PRef / wRef Type: Torque (N·m) Description: Reference stray load torque at reference angular velocity and reference current |
Modelica.Electrical.Machines.Losses.InductionMachines Model of stray load losses dependent on current and speed |
|
Modelica.Electrical.Machines.Losses.DCMachines Model of stray load losses dependent on current and speed |
|
Modelica.Electrical.Machines.Interfaces Partial model for induction machine |
|
Modelica.Electrical.Machines.Interfaces Partial model for DC machine |
|
Modelica.Electrical.Machines.Utilities.ParameterRecords Common parameters for induction machines |
|
Modelica.Electrical.Machines.Utilities.ParameterRecords Common parameters for DC machines |
|
Modelica.Magnetic.FundamentalWave.Interfaces Partial model for induction machine |
|
Modelica.Magnetic.QuasiStatic.FundamentalWave.BasicMachines.BaseClasses Partial model for quasi static multi phase machines |
|
Modelica.Magnetic.QuasiStatic.FundamentalWave.Losses Model of stray load losses dependent on current and speed |