convertResistance

Converts resistance from reference temperature to an actual temperature

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

From the temperature coefficient alpha20 at 20 degC (equals to 293.15 K) the parameter alphaRef at TRef

                        alpha20
  alphaRef = -------------------------------
              1 + alpha20 * (TRef - 293.15)

is determined; using this value, actual resistance R with respect to the actual temperature T is calculated by

   R
  ------ = 1 + alphaRef * (T - TRef)
   RRef

where RRef is the resistance at the reference temperature TRef.

Syntax

R = convertResistance(RRef, TRef, alpha20, T)

Inputs (4)

RRef

Type: Resistance (Ω)

Description: Resistance at TRef

TRef

Type: Temperature (K)

Description: Reference temperature

alpha20

Type: LinearTemperatureCoefficient (¹/K)

Description: Temperature coefficient at 20 degC

T

Type: Temperature (K)

Description: Actual temperature

Outputs (1)

R

Type: Resistance (Ω)

Description: Actual resistance at T