linearTemperatureDependencyConverts a value (e.g. resistance) from reference temperature to an actual temperature |
|
This information is part of the Modelica Standard Library maintained by the Modelica Association.
This is the same function as Modelica.Electrical.Machines.Thermal.convertResistance but without physical units for input RRef and result R. This avoids problems if the function is used to calculate linear temperature dependency for other values than resistances.
From the temperature coefficient alpha20 at 20 degC (equals to 293.15 K) the parameter alphaRef at TRef
alpha20
alphaRef = -------------------------------
1 + alpha20 * (TRef - 293.15)
is determined; using this value, actual value (e.g. resistance R) with respect to the actual temperature T is calculated by
R ------ = 1 + alphaRef * (T - TRef) RRef
where RRef is the value (e.g. resistance) at the reference temperature TRef.
| RRef |
Type: Real Description: Value at TRef |
|---|---|
| TRef |
Type: Temperature (K) Description: Reference temperature |
| alpha20 |
Type: LinearTemperatureCoefficient (ยน/K) Description: Temperature coefficient at 20 degC |
| T |
Type: Temperature (K) Description: Actual temperature |
| R |
Type: Real Description: Actual value at T |
|---|