kc_approxForcedConvectionMean convective heat transfer coefficient for forced convection | approximation | turbulent regime | hydrodynamically developed fluid flow |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Approximate calculation of the mean convective heat transfer coefficient kc for forced convection with a fully developed fluid flow in a turbulent regime.
A detailed documentation for this convective heat transfer calculation can be found in its underlying function kc_approxForcedConvection_KC . Note that additionally a failure status is observed in this function to check if the intended boundary conditions are fulfilled. See more information .
IN_con |
Type: kc_approxForcedConvection_IN_con Description: Input record for function kc_approxForcedConvection |
---|---|
IN_var |
Type: kc_approxForcedConvection_IN_var Description: Input record for function kc_approxForcedConvection |
kc |
Type: CoefficientOfHeatTransfer (W/(m²·K)) Description: Convective heat transfer coefficient |
---|---|
Pr |
Type: PrandtlNumber Description: Prandtl number |
Re |
Type: ReynoldsNumber Description: Reynolds number |
Nu |
Type: NusseltNumber Description: Nusselt number |
failureStatus |
Type: Real Description: 0== boundary conditions fulfilled | 1== failure >> check if still meaningful results |