dp_pressureLossCoefficient_DPGeneric pressure loss | calculate pressure loss | pressure loss coefficient (zeta_TOT) |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Calculation of a generic pressure loss in dependence of a pressure loss coefficient.
Generally this function is numerically best used for the incompressible case , where the mass flow rate (m_flow) is known (as state variable) in the used model and the corresponding pressure loss (DP) has to be calculated. On the other hand the function dp_pressureLossCoefficient_MFLOW is numerically best used for the compressible case if the pressure loss (dp) is known (out of pressures as state variable) and the mass flow rate (M_FLOW) has to be calculated. See more information.
IN_con |
Type: dp_pressureLossCoefficient_IN_con Description: Input record for dp_pressureLossCoefficient_DP |
---|---|
IN_var |
Type: dp_pressureLossCoefficient_IN_var Description: Input record for dp_pressureLossCoefficient_DP |
m_flow |
Type: MassFlowRate (kg/s) Description: Mass flow rate |
DP |
Type: Pressure (Pa) Description: Output for function dp_pressureLossCoefficient_DP |
---|