dp_overall_MFLOW

Pressure loss of straight pipe | calculate mass flow rate | overall flow regime | surface roughness

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Calculation of pressure loss in a straight pipe for overall flow regime of an incompressible and single-phase fluid flow only considering surface roughness.

Generally this function is numerically best used for the compressible case , where the pressure loss (dp) is known (out of pressures as state variable) in the used model and the corresponding mass flow rate (M_FLOW) has to be calculated. On the other hand the function dp_overall_DP is numerically best used for the incompressible case if the mass flow rate (m_flow) is known (as state variable) and the pressure loss (DP) has to be calculated. See more information.

Syntax

M_FLOW = dp_overall_MFLOW(IN_con, IN_var, dp)

Inputs (3)

IN_con

Type: dp_overall_IN_con

Description: Input record for function dp_overall_MFLOW

IN_var

Type: dp_overall_IN_var

Description: Input record for function dp_overall_MFLOW

dp

Type: Pressure (Pa)

Description: Pressure loss

Outputs (1)

M_FLOW

Type: MassFlowRate (kg/s)

Description: Output of function dp_overall_MFLOW