dp_severalGeometryOverall_MFLOW

Pressure loss of valve | calculate mass flow rate | several geometries | overall flow regime

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Calculation of pressure loss for a valve with different geometries at overall flow regime for incompressible and single-phase fluid flow in dependence of its opening.

Generally this function is numerically best used for the compressible case , where the pressure loss (dp) is known (out of pressures as state variable) in the used model and the corresponding mass flow rate (M_FLOW) has to be calculated. On the other hand the function dp_severalGeometryOverall_DP is numerically best used for the incompressible case if the mass flow rate (m_flow) is known (as state variable) and the pressure loss (DP) has to be calculated. See more information.

Syntax

M_FLOW = dp_severalGeometryOverall_MFLOW(IN_con, IN_var, dp)

Inputs (3)

IN_con

Type: dp_severalGeometryOverall_IN_con

Description: Input record for function dp_severalGeometryOverall_MFLOW

IN_var

Type: dp_severalGeometryOverall_IN_var

Description: Input record for function dp_severalGeometryOverall_MFLOW

dp

Type: Pressure (Pa)

Description: Pressure loss

Outputs (1)

M_FLOW

Type: MassFlowRate (kg/s)

Description: Mass flow rate