dp_severalGeometryOverall_MFLOWPressure loss of valve | calculate mass flow rate | several geometries | overall flow regime |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Calculation of pressure loss for a valve with different geometries at overall flow regime for incompressible and single-phase fluid flow in dependence of its opening.
Generally this function is numerically best used for the compressible case , where the pressure loss (dp) is known (out of pressures as state variable) in the used model and the corresponding mass flow rate (M_FLOW) has to be calculated. On the other hand the function dp_severalGeometryOverall_DP is numerically best used for the incompressible case if the mass flow rate (m_flow) is known (as state variable) and the pressure loss (DP) has to be calculated. See more information.
IN_con |
Type: dp_severalGeometryOverall_IN_con Description: Input record for function dp_severalGeometryOverall_MFLOW |
---|---|
IN_var |
Type: dp_severalGeometryOverall_IN_var Description: Input record for function dp_severalGeometryOverall_MFLOW |
dp |
Type: Pressure (Pa) Description: Pressure loss |
M_FLOW |