| TestWallFrictionPressure drop in pipe due to wall friction (only for test purposes; if needed use Pipes.StaticPipe instead) |  | 
| dp_start | Value: dp_nominal Type: AbsolutePressure (Pa) Description: Guess value of dp = port_a.p - port_b.p | 
|---|---|
| m_flow_small | Value: if system.use_eps_Re then system.eps_m_flow * m_flow_nominal else system.m_flow_small Type: MassFlowRate (kg/s) Description: Small mass flow rate for regularization of zero flow | 
| show_T | Value: true Type: Boolean Description: = true, if temperatures at port_a and port_b are computed | 
| show_V_flow | Value: true Type: Boolean Description: = true, if volume flow rate at inflowing port is computed | 
| allowFlowReversal | Value: system.allowFlowReversal Type: Boolean Description: = true to allow flow reversal, false restricts to design direction (m_flow >= 0) | 
| momentumDynamics | Value: Types.Dynamics.SteadyState Type: Dynamics Description: Formulation of momentum balance | 
| m_flow_start | Value: system.m_flow_start Type: MassFlowRate (kg/s) Description: Start value of mass flow rates | 
| data | Value: LossFactorData.wallFriction(length, diameter, roughness) Type: LossFactorData Description: Loss factor data | 
| m_flow_nominal | Value: if system.use_eps_Re then system.m_flow_nominal else 1e2 * system.m_flow_small Type: MassFlowRate (kg/s) Description: Nominal mass flow rate | 
| use_Re | Value: system.use_eps_Re Type: Boolean Description: = true, if turbulent region is defined by Re, otherwise by m_flow_small | 
| from_dp | Value: true Type: Boolean Description: = true, use m_flow = f(dp) else dp = f(m_flow) | 
| show_Re | Value: false Type: Boolean Description: = true, if Reynolds number is included for plotting | 
| length | Value: Type: Length (m) Description: Length of pipe | 
| diameter | Value: Type: Diameter (m) Description: Inner diameter of pipe | 
| roughness | Value: Type: Roughness (m) Description: Absolute roughness of pipe (> 0 required, details see info layer) | 
| pathLength | Default Value: 0 Type: Length (m) Description: Length flow path | 
|---|
|  | port_a | Type: FluidPort_a Description: Fluid connector a (positive design flow direction is from port_a to port_b) | 
|---|---|---|
|  | port_b | Type: FluidPort_b Description: Fluid connector b (positive design flow direction is from port_a to port_b) | 
|  | state_a | Type: ThermodynamicState Description: state for medium inflowing through port_a | 
|---|---|---|
|  | state_b | Type: ThermodynamicState Description: state for medium inflowing through port_b | 
|  | system | Type: System Description: System properties | 
|  | data | Type: LossFactorData Description: Loss factor data | 
|  | state_nominal | Type: ThermodynamicState Description: Medium state to compute nominal pressure drop |