| VolumeFlowRateIdeal sensor for volume flow rate |  | 
This information is part of the Modelica Standard Library maintained by the Modelica Association.
This component monitors the volume flow rate flowing from port_a to port_b. The sensor is ideal, i.e., it does not influence the fluid.
| allowFlowReversal | Value: system.allowFlowReversal Type: Boolean Description: = true to allow flow reversal, false restricts to design direction (port_a -> port_b) | 
|---|---|
| m_flow_nominal | Value: system.m_flow_nominal Type: MassFlowRate (kg/s) Description: Nominal value of m_flow = port_a.m_flow | 
| m_flow_small | Value: if system.use_eps_Re then system.eps_m_flow * m_flow_nominal else system.m_flow_small Type: MassFlowRate (kg/s) Description: Regularization for bi-directional flow in the region |m_flow| < m_flow_small (m_flow_small > 0 required) | 
|  | port_a | Type: FluidPort_a Description: Fluid connector a (positive design flow direction is from port_a to port_b) | 
|---|---|---|
|  | port_b | Type: FluidPort_b Description: Fluid connector b (positive design flow direction is from port_a to port_b) | 
|  | V_flow | Type: RealOutput Description: Volume flow rate from port_a to port_b | 
|  | system | Type: System Description: System wide properties | 
|---|