LeakageWithCoefficient

Leakage reluctance with respect to the reluctance of a useful flux path (not for dynamic simulation of actuators)

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Differently from the flux tube elements of package Shapes.Leakage that are calculated from their geometry, this leakage reluctance is calculated with reference to the total reluctance of a useful flux path. Parameter c_usefulFlux is the ratio of the useful flux over the total flux.

Parameters (1)

c_usefulFlux

Value: 0.7

Type: CouplingCoefficient

Description: Ratio useful flux/(leakage flux + useful flux) = useful flux/total flux

Inputs (1)

R_mUsefulTot

Type: Reluctance (H⁻¹)

Description: Total reluctance of useful flux path as reference

Connectors (2)

port_p

Type: PositiveMagneticPort

Description: Positive quasi-static magnetic port

port_n

Type: NegativeMagneticPort

Description: Negative quasi-static magnetic port

Components (2)

V_m

Type: ComplexMagneticPotentialDifference

Description: Magnetic potential difference of both ports

Phi

Type: ComplexMagneticFlux

Description: Magnetic flux from port_p to port_n

Used in Examples (1)

GeneralLeakage

Modelica.Magnetic.QuasiStatic.FluxTubes.Examples.Leakage

Magnetic circuit with generic leakage mode