PermeabilityDetermines permeability from flux and magnetic potential difference |
|
This information is part of the Modelica Standard Library maintained by the Modelica Association.
This model determines the absolute and relative permeability from two real inputs:


In order to calculate the permeabilities, the area of cross section,
,
and the geometric length,
,
of the flux path have to be take into account
In case that the magnetic potential difference is close to zero, permeabilities yield:
| Phi |
Type: RealInput Description: Magnetic flux |
|
|---|---|---|
| V_m |
Type: RealInput Description: Magnetic potential difference |
|
| mu |
Type: RealOutput Description: Absolute permeability |
|
| mur |
Type: RealOutput Description: Relative Permeability |
|
FundamentalWavePermabilitySensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.Transient Sensor of fundamental wave permeability |