This component models the volume of fixed size that is associated with the fluid port to which it is connected. This means that all medium properties inside the volume, are identical to the port medium properties. In particular, the specific enthalpy inside the volume (= medium.h) is always identical to the specific enthalpy in the port (port.h = medium.h). Usually, this model is used when discretizing a component according to the finite volume method into volumes in internal ports that only store energy and mass and into transport elements that just transport energy, mass and momentum between the internal ports without storing these quantities during the transport.

Parameters (8)

V

Value: 1e-6

Type: Volume (m³)

Description: Fixed size of junction volume

use_p_start

Value: true

Type: Boolean

Description: Select p_start or d_start

p_start

Value: 101325

Type: AbsolutePressure (Pa)

Description: Initial pressure

d_start

Value: 1

Type: Density (kg/m³)

Description: Initial density

use_T_start

Value: true

Type: Boolean

Description: Select T_start or h_start

T_start

Value: Modelica.SIunits.Conversions.from_degC(20)

Type: Temperature (K)

Description: Initial temperature

h_start

Value: 1.e4

Type: SpecificEnthalpy (J/kg)

Description: Initial specific enthalpy

X_start

Value:

Type: MassFraction[Medium.nX] (kg/kg)

Description: Initial mass fractions m_i/m

Connectors (1)

port

Type: FluidPort_a

Components (1)

medium

Type: BaseProperties

Used in Components (2)

PartialTestModel

Modelica.Media.Examples.Tests.Components

Basic test model to test a medium

PartialTestModel2

Modelica.Media.Examples.Tests.Components

Slightly larger test model to test a medium