Version_2_2_1Version 2.2.1 (March 24, 2006) |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Version 2.2.1 is backward compatible to version 2.2.
In this version, no new libraries have been added. The following major improvements have been made:
The following new components have been added to existing libraries:
Modelica.Blocks.Examples. | |
PID_Controller | Example to demonstrate the usage of the Blocks.Continuous.LimPID block. |
Modelica.Blocks.Math. | |
UnitConversions.* | New package that provides blocks for unit conversions. UnitConversions.ConvertAllBlocks allows to select all available conversions from a menu. |
Modelica.Electrical.Machines.BasicMachines.SynchronousInductionMachines. | |
SM_ElectricalExcitedDamperCage | Electrical excited synchronous induction machine with damper cage |
Modelica.Electrical.Machines.BasicMachines.Components. | |
ElectricalExcitation | Electrical excitation for electrical excited synchronous induction machines |
DamperCage | Unsymmetrical damper cage for electrical excited synchronous induction machines. At least the user has to specify the dampers resistance and stray inductance in d-axis; if he omits the parameters of the q-axis, the same values as for the d.axis are used, assuming a symmetrical damper. |
Modelica.Electrical.Machines.Examples. | |
SMEE_Gen | Test example 7: ElectricalExcitedSynchronousInductionMachine as Generator |
Utilities.TerminalBox | Terminal box for three-phase induction machines to choose either star (wye) ? or delta ? connection |
Modelica.Math.Matrices. | |
equalityLeastSquares | Solve a linear equality constrained least squares problem: min|A*x-a|^2 subject to B*x=b |
Modelica.Mechanics.MultiBody. | |
Parts.PointMass | Point mass, i.e., body where inertia tensor is neglected. |
Interfaces.FlangeWithBearing | Connector consisting of 1-dim. rotational flange and its 3-dim. bearing frame. |
Interfaces.FlangeWithBearingAdaptor | Adaptor to allow direct connections to the sub-connectors of FlangeWithBearing. |
Types.SpecularCoefficient | New type to define a specular coefficient. |
Types.ShapeExtra | New type to define the extra data for visual shape objects and to have a central place for the documentation of this data. |
Modelica.Mechanics.MultiBody.Examples.Elementary | |
PointGravityWithPointMasses | Example of two point masses in a central gravity field. |
Modelica.Mechanics.Rotational. | |
UsersGuide | A User's Guide has been added by using the documentation previously present in the package documentation of Rotational. |
Sensors.PowerSensor | New component to measure the energy flow between two connectors of the Rotational library. |
Modelica.Mechanics.Translational. | |
Speed | New component to move a translational flange according to a reference speed |
Modelica.Media.Interfaces.PartialMedium. | |
specificEnthalpy_pTX | New function to compute specific enthalpy from pressure, temperature and mass fractions. |
temperature_phX | New function to compute temperature from pressure, specific enthalpy, and mass fractions. |
Modelica.Icons. | |
SignalBus | Icon for signal bus |
SignalSubBus | Icon for signal sub-bus |
Modelica.SIunits. | |
UsersGuide | A User's Guide has been added that describes unit handling. |
Resistance Conductance |
Attribute 'min=0' removed from these types. |
Modelica.Thermal.FluidHeatFlow. | |
Components.Valve | Simple controlled valve with either linear or exponential characteristic. |
Sources. IdealPump | Simple ideal pump (resp. fan) dependent on the shaft's speed; pressure increase versus volume flow is defined as a linear function. Torque * Speed = Pressure increase * Volume flow (without losses). |
Examples.PumpAndValve | Test example for valves. |
Examples.PumpDropOut | Drop out of 1 pump to test behavior of semiLinear. |
Examples.ParallelPumpDropOut | Drop out of 2 parallel pumps to test behavior of semiLinear. |
Examples.OneMass | Cooling of 1 hot mass to test behavior of semiLinear. |
Examples.TwoMass | Cooling of 2 hot masses to test behavior of semiLinear. |
The following components have been improved:
Modelica. | |
UsersGuide | User's Guide and package description of Modelica Standard Library improved. |
Modelica.Blocks.Interfaces. | |
RealInput BooleanInput IntegerInput |
When dragging one of these connectors the width and height is a factor of 2 larger as a standard icon. Previously, these connectors have been dragged and then manually enlarged by a factor of 2 in the Modelica standard library. |
Modelica.Blocks. | |
Continuous.* | Initialization options added to all blocks (NoInit, SteadyState, InitialState, InitialOutput). New parameter limitsAtInit to switch off the limits of LimIntegrator or LimPID during initialization |
Continuous.LimPID | Option to select P, PI, PD, PID controller. Documentation significantly improved. |
Nonlinear.Limiter Nonlinear.VariableLimiter Nonlinear.Deadzone |
New parameter limitsAtInit/deadZoneAtInit to switch off the limits or the dead zone during initialization |
Modelica.Electrical.Analog. | |
Sources | Icon improved (+/- added to voltage sources, arrow added to current sources). |
Modelica.Electrical.Analog.Semiconductors. | |
Diode | smooth() operator included to improve numerics. |
Modelica.Electrical.Machines.BasicMachines.SynchronousInductionMachines. | |
SM_PermanentMagnetDamperCage SM_ElectricalExcitedDamperCage SM_ReluctanceRotorDamperCage |
The user can choose "DamperCage = false" (default: true) to remove all equations for the damper cage from the model. |
Modelica.Electrical.Machines.BasicMachines.AsynchronousInductionMachines. | |
AIM_SlipRing | Easier parameterization: if the user selects "useTurnsRatio = false" (default: true, this is the same behavior as before), parameter TurnsRatio is calculated internally from Nominal stator voltage and Locked-rotor voltage. |
Modelica.Math.Matrices. | |
leastSquares | The A matrix in the least squares problem might be rank deficient. Previously, it was required that A has full rank. |
Modelica.Mechanics.MultiBody. | |
all models |
|
Frames.resolveRelative | The derivative of this function added as function and defined via an annotation. In certain situations, tools had previously difficulties to differentiate the inlined function automatically. |
Forces.* | The scaling factors N_to_m and Nm_to_m have no longer a default value of 1000 but a default value of world.defaultN_to_m (=1000) and world.defaultNm_to_m (=1000). This allows to change the scaling factors for all forces and torques in the world object. |
Interfaces.Frame.a Interfaces.Frame.b Interfaces.Frame_resolve |
The Frame connectors are now centered around the origin to ease the usage. The shape was changed, such that the icon is a factor of 1.6 larger as a standard icon (previously, the icon had a standard size when dragged and then the icon was manually enlarged by a factor of 1.5 in the y-direction in the MultiBody library; the height of 16 allows easy positioning on the standard grid size of 2). The double line width of the border in icon and diagram layer was changed to a single line width and when making a connection the connection line is dark grey and no longer black which looks better. |
Joints.Assemblies.* | When dragging an assembly joint, the icon is a factor of 2 larger as a standard icon. Icon texts and connectors have a standard size in this enlarged icon (and are not a factor of 2 larger as previously). |
Types.* | All types have a corresponding icon now to visualize the content in the package browser (previously, the types did not have an icon). |
Modelica.Mechanics.Rotational. | |
Inertia | Initialization and state selection added. |
SpringDamper | Initialization and state selection added. |
Move | New implementation based solely on Modelica 2.2 language (previously, the Dymola specific constrain(..) function was used). |
Modelica.Mechanics.Translational. | |
Move | New implementation based solely on Modelica 2.2 language (previously, the Dymola specific constrain(..) function was used). |
Modelica.Thermal.FluidHeatFlow.Interfaces.Partials. | |
SimpleFriction | Calculates friction losses from pressure drop and volume flow. |
Modelica.Thermal.FluidHeatFlow.Components. | |
IsolatedPipe HeatedPipe |
Added geodetic height as a source of pressure change; feeds friction losses as calculated by simple friction to the energy balance of the medium. |
Modelica.Media.Interfaces.PartialMedium.FluidConstants. | |
HCRIT0 | Critical specific enthalpy of the fundamental equation (base formulation of the fluid medium model). |
SCRIT0 | Critical specific entropy of the fundamental equation (base formulation of the fluid medium model). |
deltah | Enthalpy offset (default: 0) between the specific enthalpy of the fluid model and the user-visible specific enthalpy in the model: deltah = h_model - h_fundamentalEquation. |
deltas | Entropy offset (default: 0) between the specific entropy of the fluid model and the user-visible specific entropy in the model: deltas = s_model - s_fundamentalEquation. |
T_default | Default value for temperature of medium (for initialization) |
h_default | Default value for specific enthalpy of medium (for initialization) |
p_default | Default value for pressure of medium (for initialization) |
X_default | Default value for mass fractions of medium (for initialization) |
The following errors have been fixed:
Modelica.Blocks.Tables. | |
CombiTable1D CombiTable1Ds CombiTable2D |
Parameter "tableOnFile" determines now whether a table is read from
file or used from parameter "table". Previously, if "fileName" was not
"NoName", a table was always read from file "fileName", independently
of the setting of "tableOnFile". This has been corrected. Furthermore, the initialization of a table is now performed in a when-clause and no longer in a parameter declaration, because some tools evaluate the parameter declaration in some situation more than once and then the table is unnecessarily read several times (and occupies also more memory). |
Modelica.Blocks.Sources. | |
CombiTimeTable | Same bug fix/improvement as for the tables from Modelica.Blocks.Tables as outlined above. |
Modelica.Electrical.Analog.Semiconductors. | |
PMOS NMOS HeatingPMOS HeatingNMOS |
The Drain-Source-Resistance RDS had actually a resistance of
RDS/v, with v=Beta*(W+dW)/(L+dL). The correct formula is without
the division by "v". This has now been corrected. This bug fix should not have an essential effect in most applications. In the default case (Beta=1e-5), the Drain-Source-Resistance was a factor of 1e5 too large and had in the default case the wrong value 1e12, although it should have the value 1e7. The effect was that this resistance had practically no effect. |
Modelica.Media.IdealGases.Common.SingleGasNasa. | |
dynamicViscosityLowPressure | Viscosity and thermal conductivity (which needs viscosity as input) were computed wrong for polar gases and gas mixtures (i.e., if dipole moment not 0.0). This has been fixed in version 2.2.1. |
Modelica.Utilities.Streams. | |
readLine | Depending on the C-implementation, the stream was not correctly closed. This has been corrected by adding a "Streams.close(..)" after reading the file content. |