Transformers: primary D / secondary zig-zag
Extends from Modelica.Icons.VariantsPackage (Icon for package containing variants).
| Name | Description | 
|---|---|
|  Dz00 | Transformer Dz0 | 
|  Dz02 | Transformer Dz2 | 
|  Dz04 | Transformer Dz4 | 
|  Dz06 | Transformer Dz6 | 
|  Dz08 | Transformer Dz8 | 
|  Dz10 | Transformer Dz10 | 
 Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz00
Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz00Transformer Dz0
Extends from Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).
| Name | Description | 
|---|---|
| n | Ratio primary voltage (line-to-line) / secondary voltage (line-to-line) | 
| useThermalPort | Enable / disable (=fixed temperatures) thermal port | 
| Operational temperatures | |
| T1Operational | Operational temperature of primary resistance [K] | 
| T2Operational | Operational temperature of secondary resistance [K] | 
| Nominal resistances and inductances | |
| R1 | Primary resistance per phase at TRef [Ohm] | 
| T1Ref | Reference temperature of primary resistance [K] | 
| alpha20_1 | Temperature coefficient of primary resistance at 20 degC [1/K] | 
| L1sigma | Primary stray inductance per phase [H] | 
| R2 | Secondary resistance per phase at TRef [Ohm] | 
| T2Ref | Reference temperature of secondary resistance [K] | 
| alpha20_2 | Temperature coefficient of secondary resistance at 20 degC [1/K] | 
| L2sigma | Secondary stray inductance per phase [H] | 
| Name | Description | 
|---|---|
| plug1 | Primary plug | 
| plug2 | Secondary plug | 
| thermalPort | |
| starpoint2 | 
 Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz02
Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz02Transformer Dz2
Extends from Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).
| Name | Description | 
|---|---|
| n | Ratio primary voltage (line-to-line) / secondary voltage (line-to-line) | 
| useThermalPort | Enable / disable (=fixed temperatures) thermal port | 
| Operational temperatures | |
| T1Operational | Operational temperature of primary resistance [K] | 
| T2Operational | Operational temperature of secondary resistance [K] | 
| Nominal resistances and inductances | |
| R1 | Primary resistance per phase at TRef [Ohm] | 
| T1Ref | Reference temperature of primary resistance [K] | 
| alpha20_1 | Temperature coefficient of primary resistance at 20 degC [1/K] | 
| L1sigma | Primary stray inductance per phase [H] | 
| R2 | Secondary resistance per phase at TRef [Ohm] | 
| T2Ref | Reference temperature of secondary resistance [K] | 
| alpha20_2 | Temperature coefficient of secondary resistance at 20 degC [1/K] | 
| L2sigma | Secondary stray inductance per phase [H] | 
| Name | Description | 
|---|---|
| plug1 | Primary plug | 
| plug2 | Secondary plug | 
| thermalPort | |
| starpoint2 | 
 Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz04
Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz04Transformer Dz4
Extends from Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).
| Name | Description | 
|---|---|
| n | Ratio primary voltage (line-to-line) / secondary voltage (line-to-line) | 
| useThermalPort | Enable / disable (=fixed temperatures) thermal port | 
| Operational temperatures | |
| T1Operational | Operational temperature of primary resistance [K] | 
| T2Operational | Operational temperature of secondary resistance [K] | 
| Nominal resistances and inductances | |
| R1 | Primary resistance per phase at TRef [Ohm] | 
| T1Ref | Reference temperature of primary resistance [K] | 
| alpha20_1 | Temperature coefficient of primary resistance at 20 degC [1/K] | 
| L1sigma | Primary stray inductance per phase [H] | 
| R2 | Secondary resistance per phase at TRef [Ohm] | 
| T2Ref | Reference temperature of secondary resistance [K] | 
| alpha20_2 | Temperature coefficient of secondary resistance at 20 degC [1/K] | 
| L2sigma | Secondary stray inductance per phase [H] | 
| Name | Description | 
|---|---|
| plug1 | Primary plug | 
| plug2 | Secondary plug | 
| thermalPort | |
| starpoint2 | 
 Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz06
Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz06Transformer Dz6
Extends from Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).
| Name | Description | 
|---|---|
| n | Ratio primary voltage (line-to-line) / secondary voltage (line-to-line) | 
| useThermalPort | Enable / disable (=fixed temperatures) thermal port | 
| Operational temperatures | |
| T1Operational | Operational temperature of primary resistance [K] | 
| T2Operational | Operational temperature of secondary resistance [K] | 
| Nominal resistances and inductances | |
| R1 | Primary resistance per phase at TRef [Ohm] | 
| T1Ref | Reference temperature of primary resistance [K] | 
| alpha20_1 | Temperature coefficient of primary resistance at 20 degC [1/K] | 
| L1sigma | Primary stray inductance per phase [H] | 
| R2 | Secondary resistance per phase at TRef [Ohm] | 
| T2Ref | Reference temperature of secondary resistance [K] | 
| alpha20_2 | Temperature coefficient of secondary resistance at 20 degC [1/K] | 
| L2sigma | Secondary stray inductance per phase [H] | 
| Name | Description | 
|---|---|
| plug1 | Primary plug | 
| plug2 | Secondary plug | 
| thermalPort | |
| starpoint2 | 
 Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz08
Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz08Transformer Dz8
Extends from Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).
| Name | Description | 
|---|---|
| n | Ratio primary voltage (line-to-line) / secondary voltage (line-to-line) | 
| useThermalPort | Enable / disable (=fixed temperatures) thermal port | 
| Operational temperatures | |
| T1Operational | Operational temperature of primary resistance [K] | 
| T2Operational | Operational temperature of secondary resistance [K] | 
| Nominal resistances and inductances | |
| R1 | Primary resistance per phase at TRef [Ohm] | 
| T1Ref | Reference temperature of primary resistance [K] | 
| alpha20_1 | Temperature coefficient of primary resistance at 20 degC [1/K] | 
| L1sigma | Primary stray inductance per phase [H] | 
| R2 | Secondary resistance per phase at TRef [Ohm] | 
| T2Ref | Reference temperature of secondary resistance [K] | 
| alpha20_2 | Temperature coefficient of secondary resistance at 20 degC [1/K] | 
| L2sigma | Secondary stray inductance per phase [H] | 
| Name | Description | 
|---|---|
| plug1 | Primary plug | 
| plug2 | Secondary plug | 
| thermalPort | |
| starpoint2 | 
 Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz10
Modelica.Electrical.Machines.BasicMachines.Transformers.Dz.Dz10Transformer Dz10
Extends from Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).
| Name | Description | 
|---|---|
| n | Ratio primary voltage (line-to-line) / secondary voltage (line-to-line) | 
| useThermalPort | Enable / disable (=fixed temperatures) thermal port | 
| Operational temperatures | |
| T1Operational | Operational temperature of primary resistance [K] | 
| T2Operational | Operational temperature of secondary resistance [K] | 
| Nominal resistances and inductances | |
| R1 | Primary resistance per phase at TRef [Ohm] | 
| T1Ref | Reference temperature of primary resistance [K] | 
| alpha20_1 | Temperature coefficient of primary resistance at 20 degC [1/K] | 
| L1sigma | Primary stray inductance per phase [H] | 
| R2 | Secondary resistance per phase at TRef [Ohm] | 
| T2Ref | Reference temperature of secondary resistance [K] | 
| alpha20_2 | Temperature coefficient of secondary resistance at 20 degC [1/K] | 
| L2sigma | Secondary stray inductance per phase [H] | 
| Name | Description | 
|---|---|
| plug1 | Primary plug | 
| plug2 | Secondary plug | 
| thermalPort | |
| starpoint2 |