Loss models for electric machines
Extends from Modelica.Icons.Package (Icon for standard packages).
Name | Description |
---|---|
FrictionParameters | Parameter record for friction losses |
BrushParameters | Parameter record for brush losses |
StrayLoadParameters | Parameter record for stray load losses |
CoreParameters | Parameter record for core losses |
PermanentMagnetLossParameters | Parameter record for permanent magnet losses |
Friction | Model of angular velocity dependent friction losses |
InductionMachines | Loss models for induction machines |
DCMachines | Loss models for DC machines |
Parameter record for friction losses
Parameter record for Friction losses.
Extends from Modelica.Icons.Record (Icon for records).
Name | Description |
---|---|
PRef | Reference friction losses at wRef [W] |
wRef | Reference angular velocity that the PRef refer to [rad/s] |
power_w | Exponent of friction torque w.r.t. angular velocity |
Parameter record for brush losses
Parameter record for three-phase Brush and DC Brush losses.
Extends from Modelica.Icons.Record (Icon for records).
Name | Description |
---|---|
V | Total voltage drop of brushes for currents > ILinear [V] |
ILinear | Current indicating linear voltage region of brush voltage drop [A] |
Parameter record for stray load losses
Parameter record for three-phase and DC stray load losses.
Extends from Modelica.Icons.Record (Icon for records).
Name | Description |
---|---|
PRef | Reference stray load losses at IRef and wRef [W] |
IRef | Reference RMS current that PRef refers to [A] |
wRef | Reference angular velocity that PRef refers to [rad/s] |
power_w | Exponent of stray load loss torque w.r.t. angular velocity |
Parameter record for core losses
Parameter record for core losses of induction machines and core losses of DC machines.
Extends from Modelica.Icons.Record (Icon for records).
Name | Description |
---|---|
m | Number of phases (1 for DC, 3 for induction machines) |
PRef | Reference core losses at reference inner voltage VRef [W] |
VRef | Reference inner RMS voltage that reference core losses PRef refer to [V] |
wRef | Reference angular velocity that reference core losses PRef refer to [rad/s] |
Parameter record for permanent magnet losses
Parameter record for permanent magnet losses.
Extends from Modelica.Icons.Record (Icon for records).
Name | Description |
---|---|
PRef | Reference permanent magnet losses at IRef and wRef [W] |
c | Part of permanent magnet losses at current = 0, i.e. independent of current |
IRef | Reference stator RMS current that PRef refers to [A] |
power_I | Exponent of permanent magnet loss torque w.r.t. stator current |
wRef | Reference angular velocity that PRef refers to [rad/s] |
power_w | Exponent of permanent magnet loss torque w.r.t. angular velocity |
Model of angular velocity dependent friction losses
The friction losses are considered by the equations
tau / tauRef = (+w / wRef) ^ power_w for w > +wLinear - tau / tauRef = (-w / wRef) ^ power_w for w < -wLinear
with
tauRef * wRef = PRef
being the friction torque at the reference angular velocity
wRef
. The exponent power_w
is
approximately 1.5 for axial ventilation and approximately 2.0 for radial ventilation.
For stability reasons the friction torque tau
is approximated by a linear curve
tau / tauLinear = w / wLinear
with
tauLinear = tauRef*(wLinear/wRef) ^ power_w
in the range -wLinear ≤ w ≤ wLinear
with wLinear = 0.001 * wRef
. The relationship of torque
and angular velocity is depicted in Fig. 1
Fig. 1: Friction loss torque versus angular velocity for power_w = 2 |
If it is desired to neglect friction losses, set frictionParameters.PRef = 0
(this is the default).
Extends from Machines.Interfaces.FlangeSupport (Shaft and support), Modelica.Thermal.HeatTransfer.Interfaces.PartialElementaryConditionalHeatPortWithoutT (Partial model to include a conditional HeatPort in order to dissipate losses, used for textual modeling, i.e., for elementary models).
Name | Description |
---|---|
frictionParameters | Friction loss parameters |
useHeatPort | = true, if heatPort is enabled |
Name | Description |
---|---|
flange | Shaft end |
support | Housing and support |
heatPort | Optional port to which dissipated losses are transported in form of heat |