Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse

Center tap rectifier with two pulses

Information

This package includes single-phase two pulse center tap rectifiers. The examples show uncontrolled and controlled rectifiers with constant and variable firing angle.

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

Name Description
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.DiodeCenterTap2Pulse DiodeCenterTap2Pulse Two pulse diode rectifier with center tap with resistive load
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_R ThyristorCenterTap2Pulse_R Two pulse thyristor rectifier with center tap and resistive load
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_RL ThyristorCenterTap2Pulse_RL Two pulse thyristor rectifier with center tap and R-L load
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_RLV ThyristorCenterTap2Pulse_RLV Two pulse thyristor rectifier with center tap and R-L load and voltage
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_RLV_Characteristic ThyristorCenterTap2Pulse_RLV_Characteristic Characteristic of two pulse thyristor rectifier with center tap and R-L load and voltage

Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.DiodeCenterTap2Pulse Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.DiodeCenterTap2Pulse

Two pulse diode rectifier with center tap with resistive load

Information

This example shows an uncontrolled two pulse center tap diode rectifier with resistive load.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
VrmsRMS supply voltage [V]
fFrequency [Hz]
RLoad resistance [Ohm]

Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_R Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_R

Two pulse thyristor rectifier with center tap and resistive load

Information

This example shows a controlled center tap two pulse rectifier with resistive load.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
VrmsRMS supply voltage [V]
fFrequency [Hz]
constantFiringAngleFiring angle [rad]
RLoad resistance [Ohm]

Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_RL Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_RL

Two pulse thyristor rectifier with center tap and R-L load

Information

This example shows a controlled center tap two pulse rectifier with R-L load.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
VrmsRMS supply voltage [V]
fFrequency [Hz]
constantFiringAngleFiring angle [rad]
RLoad resistance [Ohm]
LLoad resistance [H]

Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_RLV Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_RLV

Two pulse thyristor rectifier with center tap and R-L load and voltage

Information

This example shows a controlled center tap two pulse rectifier with R-L load including DC voltage source. The additional DC voltage source in this example enables negative average load voltages.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
VrmsRMS supply voltage [V]
fFrequency [Hz]
constantFiringAngleFiring angle [rad]
RLoad resistance [Ohm]
LLoad resistance [H]
VDCDC load offset voltage [V]

Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_RLV_Characteristic Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_RLV_Characteristic

Characteristic of two pulse thyristor rectifier with center tap and R-L load and voltage

Information

This example shows a controlled center tap two pulse rectifier with R-L load including DC voltage source. The additional DC voltage source in this example enables negative average load voltages.

Plot average voltage meanVoltage.v versus firingAngle pulse2.firingAngle to see control characteristic of this type of rectifier with R-L load including active voltage.

Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
VrmsRMS supply voltage [V]
fFrequency [Hz]
RLoad resistance [Ohm]
LLoad resistance [H]
VDCDC load offset voltage [V]
Automatically generated Thu Oct 1 16:07:43 2020.