m pulse rectifier with center tap
This package includes polyphase center tap rectifiers. The number of phases, m
, equals the number of pulses. The examples show uncontrolled and controlled rectifiers with constant and variable firing angle.
Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).
Name | Description |
---|---|
DiodeCenterTapmPulse | 2*m pulse diode rectifier with center tap with resistive load |
ThyristorCenterTapmPulse_R | 2*m pulse thyristor rectifier with center tap and resistive load |
ThyristorCenterTapmPulse_RL | 2*m pulse thyristor rectifier with center tap and R-L load |
ThyristorCenterTapmPulse_RLV | 2*m pulse thyristor rectifier with center tap and R-L load and voltage |
ThyristorCenterTapmPulse_RLV_Characteristic | Characteristic of 2*m pulse thyristor rectifier with center tap and R-L load and voltage |
2*m pulse diode rectifier with center tap with resistive load
This example shows an uncontrolled m
pulse center tap diode rectifier with resistive load, where m
is the number of phases.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from Modelica.Icons.Example (Icon for runnable examples).
Name | Description |
---|---|
m | Number of phases |
Vrms | RMS supply voltage [V] |
f | Frequency [Hz] |
R | Load resistance [Ohm] |
2*m pulse thyristor rectifier with center tap and resistive load
This example shows a controlled m
pulse center tap rectifier with resistive load, where m
is the number of phases.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from ExampleTemplates.ThyristorCenterTapmPulse (Template of 2*m pulse rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Name | Description |
---|---|
m | Number of phases |
Vrms | RMS supply voltage [V] |
f | Frequency [Hz] |
constantFiringAngle | Firing angle [rad] |
R | Load resistance [Ohm] |
2*m pulse thyristor rectifier with center tap and R-L load
This example shows a controlled m
pulse center tap rectifier with R-L load, where m
is the number of phases.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from ExampleTemplates.ThyristorCenterTapmPulse (Template of 2*m pulse rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Name | Description |
---|---|
m | Number of phases |
Vrms | RMS supply voltage [V] |
f | Frequency [Hz] |
constantFiringAngle | Firing angle [rad] |
R | Load resistance [Ohm] |
L | Load resistance [H] |
2*m pulse thyristor rectifier with center tap and R-L load and voltage
This example shows a controlled m
pulse center tap rectifier with R-L load including DC voltage source, where m
is the number of phases. The additional DC voltage source in this example enables negative average load voltages.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
Extends from ExampleTemplates.ThyristorCenterTapmPulse (Template of 2*m pulse rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Name | Description |
---|---|
m | Number of phases |
Vrms | RMS supply voltage [V] |
f | Frequency [Hz] |
constantFiringAngle | Firing angle [rad] |
R | Load resistance [Ohm] |
L | Load resistance [H] |
VDC | DC load offset voltage [V] |
Characteristic of 2*m pulse thyristor rectifier with center tap and R-L load and voltage
This example shows a controlled m
pulse center tap rectifier with R-L load including DC voltage source, where m
is the number of phases. The additional DC voltage source in this example enables negative average load voltages.
Plot average voltage meanVoltage.v
versus firingAngle pulsem.firingAngle
to see control characteristic of this type of rectifier with R-L load including active voltage.
Extends from ExampleTemplates.ThyristorCenterTapmPulse (Template of 2*m pulse rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Name | Description |
---|---|
m | Number of phases |
Vrms | RMS supply voltage [V] |
f | Frequency [Hz] |
R | Load resistance [Ohm] |
L | Load resistance [H] |
VDC | DC load offset voltage [V] |