Modelica.Electrical.QuasiStatic.Polyphase.Examples

Test examples

Information

Examples to demonstrate the usage of quasi-static electric components.

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

Name Description
Modelica.Electrical.QuasiStatic.Polyphase.Examples.BalancingStar BalancingStar Balancing an unsymmetrical star-connected load
Modelica.Electrical.QuasiStatic.Polyphase.Examples.BalancingDelta BalancingDelta Balancing an unsymmetrical delta-connected load
Modelica.Electrical.QuasiStatic.Polyphase.Examples.UnsymmetricalLoad UnsymmetricalLoad Unsymmetrical three-phase load
Modelica.Electrical.QuasiStatic.Polyphase.Examples.TestSensors TestSensors  

Modelica.Electrical.QuasiStatic.Polyphase.Examples.BalancingStar Modelica.Electrical.QuasiStatic.Polyphase.Examples.BalancingStar

Balancing an unsymmetrical star-connected load

Information

For the unsymmetrical load (resistor, capacitor and inductor) the parameters inductance L and capacitance C are chosen such way that the neutral current (see currentSensor0) is zero.

P.Vaske, Berechnung von Drehstromschaltungen (German, Calculation of polyphase circuits), Teubner 1973, page 42, example 18

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
VSource Voltage [V]
fSource frequency [Hz]
RLoad resistance [Ohm]
LLoad inductance [H]
CLoad capacitance [F]

Modelica.Electrical.QuasiStatic.Polyphase.Examples.BalancingDelta Modelica.Electrical.QuasiStatic.Polyphase.Examples.BalancingDelta

Balancing an unsymmetrical delta-connected load

Information

For the unsymmetrical load (resistor, capacitor and inductor) the parameters inductance L and capacitance C are chosen such way that the magnitudes of the three-phase currents (see currentSensor12, currentSensor23, currentSensor31) are equal.

P.Vaske, Berechnung von Drehstromschaltungen (German, Calculation of polyphase circuits), Teubner 1973, page 43, example 23

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of phases
V_LLSource voltage line-to-line [V]
fSource frequency [Hz]
RLoad resistance [Ohm]
LLoad inductance [H]
CLoad capacitance [F]

Modelica.Electrical.QuasiStatic.Polyphase.Examples.UnsymmetricalLoad Modelica.Electrical.QuasiStatic.Polyphase.Examples.UnsymmetricalLoad

Unsymmetrical three-phase load

Information

This example shows an unsymmetrical load, in the upper with neutral connection (the single-phase current sensor measures the neutral current) and in the lower without neutral connection (the single-phase voltage sensor measures the neutral displacement).

Extends from Modelica.Icons.Example (Icon for runnable examples).

Modelica.Electrical.QuasiStatic.Polyphase.Examples.TestSensors Modelica.Electrical.QuasiStatic.Polyphase.Examples.TestSensors

Information

Test quasi-static polyphase sensors: A sinusoidal source feeds a load consisting of resistor and inductor.

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
VRMSNominal RMS voltage per phase [V]
fFrequency [Hz]
RLoad resistance [Ohm]
LLoad inductance [H]
Automatically generated Thu Oct 1 16:07:46 2020.