Modelica.Fluid.Fittings.Bends

Flow models for bends

Information

Extends from Modelica.Icons.VariantsPackage (Icon for package containing variants).

Package Content

Name Description
Modelica.Fluid.Fittings.Bends.CurvedBend CurvedBend Curved bend flow model
Modelica.Fluid.Fittings.Bends.EdgedBend EdgedBend Edged bend flow model

Modelica.Fluid.Fittings.Bends.CurvedBend Modelica.Fluid.Fittings.Bends.CurvedBend

Curved bend flow model

Information

This component models a curved bend in the overall flow regime for incompressible and single-phase fluid flow through circular cross sectional area considering surface roughness. It is expected that also compressible fluid flow can be handled up to about Ma = 0.3. It is assumed that neither mass nor energy is stored in this component. In the model basically a function is called to compute the mass flow rate as a function of pressure loss for a curved bend. Also the inverse of this function is defined, and a tool might use this inverse function instead, in order to avoid the solution of a nonlinear equation.

The details of the model are described in the documentation of the underlying function.

Extends from Modelica.Fluid.Dissipation.Utilities.Icons.PressureLoss.Bend_i (Icon for bend), Modelica.Fluid.Interfaces.PartialPressureLoss (Base flow model for pressure loss functions with the same area at port_a and at port_b).

Parameters

NameDescription
replaceable package MediumMedium in the component
geometryGeometry of curved bend
Assumptions
allowFlowReversal= true to allow flow reversal, false restricts to design direction (port_a -> port_b)
Advanced
dp_startGuess value of dp = port_a.p - port_b.p [Pa]
m_flow_startGuess value of m_flow = port_a.m_flow [kg/s]
m_flow_smallSmall mass flow rate for regularization of zero flow [kg/s]
Diagnostics
show_T= true, if temperatures at port_a and port_b are computed
show_V_flow= true, if volume flow rate at inflowing port is computed

Connectors

NameDescription
port_aFluid connector a (positive design flow direction is from port_a to port_b)
port_bFluid connector b (positive design flow direction is from port_a to port_b)

Modelica.Fluid.Fittings.Bends.EdgedBend Modelica.Fluid.Fittings.Bends.EdgedBend

Edged bend flow model

Information

This component models an edged bend in the overall flow regime for incompressible and single-phase fluid flow through circular cross sectional area considering surface roughness. It is expected that also compressible fluid flow can be handled up to about Ma = 0.3. It is assumed that neither mass nor energy is stored in this component. In the model basically a function is called to compute the mass flow rate as a function of pressure loss for an edged bend. Also the inverse of this function is defined, and a tool might use this inverse function instead, in order to avoid the solution of a nonlinear equation.

The details of the model are described in the documentation of the underlying function.

Extends from Modelica.Fluid.Dissipation.Utilities.Icons.PressureLoss.Bend_i (Icon for bend), Modelica.Fluid.Interfaces.PartialPressureLoss (Base flow model for pressure loss functions with the same area at port_a and at port_b).

Parameters

NameDescription
replaceable package MediumMedium in the component
geometryGeometry of curved bend
Assumptions
allowFlowReversal= true to allow flow reversal, false restricts to design direction (port_a -> port_b)
Advanced
dp_startGuess value of dp = port_a.p - port_b.p [Pa]
m_flow_startGuess value of m_flow = port_a.m_flow [kg/s]
m_flow_smallSmall mass flow rate for regularization of zero flow [kg/s]
Diagnostics
show_T= true, if temperatures at port_a and port_b are computed
show_V_flow= true, if volume flow rate at inflowing port is computed

Connectors

NameDescription
port_aFluid connector a (positive design flow direction is from port_a to port_b)
port_bFluid connector b (positive design flow direction is from port_a to port_b)