Components to be used in examples
Extends from Modelica.Icons.Package (Icon for standard packages).
Name | Description |
---|---|
![]() |
Single-phase transformer with ferromagnetic core and hysteresis |
![]() |
Three-phase transformer in Yy configuration |
Single-phase transformer with ferromagnetic core and hysteresis
Simple model of a single-phase transformer with a primary and a secondary winding and a magnetic core. The core is modeled with GenericHystTellinenEverett flux tube elements. Thus, this element considers static and dynamic hysteresis.
![]() |
Extends from Interfaces.ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network).
Name | Description |
---|---|
Electrical | |
Primary winding | |
N1 | Primary turns |
L1 | Mean primary turn length [m] |
d1 | Wire diameter of primary turns [m] |
rho1 | Resistivity of primary winding (at 20degC) [Ohm.m] |
alpha1 | Temperature coefficient of primary turns [1/K] |
Secondary winding | |
N2 | Secondary turns |
L2 | Mean secondary turn length [m] |
d2 | Wire diameter of secondary turns [m] |
rho2 | Resistivity of secondary winding (at 20degC) [Ohm.m] |
alpha2 | Temperature coefficient of secondary turns [1/K] |
Core | |
Geometry | |
l1 | Mean Length l1 of core [m] |
![]() | |
l2 | Mean Length l2 of core [m] |
a | Height of core [m] |
b | Width of core [m] |
Material | |
mat | Parameter set of ferromagnetic Hysteresis |
Initialization | |
MagRelStart | Initial magnetization of Core (-1..1) |
MagRelFixed | Fixed |
HStart | Initial magnetic field strength of Core [A/m] |
HFixed | Fixed |
I1Start | Initial primary current through winding [A] |
I1Fixed | Fixed |
Losses and heat | |
HeatPort | |
useHeatPort | = true, if HeatPort is enabled |
T | Fixed device temperature if useHeatPort = false [K] |
Eddy currents | |
EddyCurrents | Enable eddy currents |
sigma | Conductivity of core material [S/m] |
t | Thickness of lamination [m] |
Leakage | |
L_l1 | Length of leakage of primary Winding [m] |
A_l1 | Cross section of leakage of primary Winding [m2] |
mu_rel1 | Constant relative permeability of primary leakage (>0 required) |
L_l2 | Length of leakage of secondary Winding [m] |
A_l2 | Cross section of leakage of secondary Winding [m2] |
mu_rel2 | Constant relative permeability of secondary leakage (>0 required) |
Name | Description |
---|---|
n1 | Negative pin of primary winding |
p1 | Positive pin of primary winding |
n2 | Negative pin of secondary winding |
p2 | Positive pin of secondary winding |
heatPort |
Three-phase transformer in Yy configuration
Simple model of a three-phase transformer with primary and a secondary windings and a magnetic E-I shaped core. The core is modeled with GenericHystTellinenEverett flux tube elements. Thus, this model considers static and dynamic hysteresis as well as initial flux.
![]() |
Extends from Interfaces.ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network).
Name | Description |
---|---|
Electrical | |
Primary winding | |
N1 | Primary turns |
L1 | Mean primary turn length [m] |
d1 | Wire diameter of primary turns [m] |
rho1 | Resistivity of primary winding (at 20degC) [Ohm.m] |
alpha1 | Temperature coefficient of primary turns [1/K] |
Secondary winding | |
N2 | Secondary turns |
L2 | Mean secondary turn length [m] |
d2 | Wire diameter of secondary turns [m] |
rho2 | Resistivity of secondary winding (at 20degC) [Ohm.m] |
alpha2 | Temperature coefficient of secondary turns [1/K] |
Core | |
Geometry | |
l1 | Mean length l1 of core [m] |
![]() | |
l2 | Mean length l2 of core [m] |
a | Height of core [m] |
b | Width of core [m] |
Material | |
mat | Core Material |
Initialization | |
MagRelStart[3] | Initial magnetization of Core (-1..1) |
MagRelFixed[3] | Fixed |
HStart[3] | Initial magnetic field strength of Core [A/m] |
HFixed[3] | Fixed |
I1Start[3] | Initial current of primary Windings [A] |
I1Fixed[3] | Fixed |
I2Start[3] | Initial current of secondary Windings [A] |
I2Fixed[3] | Fixed |
Losses and heat | |
HeatPort | |
useHeatPort | = true, if HeatPort is enabled |
T | Fixed device temperature if useHeatPort = false [K] |
Eddy currents | |
EddyCurrents | Enable eddy currents |
sigma | Conductivity of core material [S/m] |
t | Thickness of lamination [m] |
Leakage | |
L_l1 | Length of leakage of primary Winding [m] |
A_l1 | Cross section of leakage of primary Winding [m2] |
mu_rel1 | Constant relative permeability of primary leakage (>0 required) |
L_l2 | Cross section of leakage of secondary Winding [m] |
A_l2 | Length of leakage of secondary Winding [m2] |
mu_rel2 | Constant relative permeability of secondary leakage (>0 required) |
Name | Description |
---|---|
heatPort | |
p1 | Primary winding 1 |
p2 | Primary winding 2 |
p3 | Primary winding 3 |
n1 | Secondary winding 1 |
n2 | Secondary winding 2 |
n3 | Secondary winding 3 |
starPoint2 | Star point of secondary windings |
starPoint1 | Star point of primary windings |