Components to be used in examples
Extends from Modelica.Icons.Package (Icon for standard packages).
Name | Description |
---|---|
Transformer1PhaseWithHysteresis | Single-phase transformer with ferromagnetic core and hysteresis |
Transformer3PhaseYyWithHysteresis | Three-phase transformer in Yy configuration |
Single-phase transformer with ferromagnetic core and hysteresis
Simple model of a single-phase transformer with a primary and a secondary winding and a magnetic core. The core is modeled with GenericHystTellinenEverett flux tube elements. Thus, this element considers static and dynamic hysteresis.
Extends from Interfaces.ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network).
Name | Description |
---|---|
Electrical | |
Primary winding | |
N1 | Primary turns |
L1 | Mean primary turn length [m] |
d1 | Wire diameter of primary turns [m] |
rho1 | Resistivity of primary winding (at 20degC) [Ohm.m] |
alpha1 | Temperature coefficient of primary turns [1/K] |
Secondary winding | |
N2 | Secondary turns |
L2 | Mean secondary turn length [m] |
d2 | Wire diameter of secondary turns [m] |
rho2 | Resistivity of secondary winding (at 20degC) [Ohm.m] |
alpha2 | Temperature coefficient of secondary turns [1/K] |
Core | |
Geometry | |
l1 | Mean Length l1 of core [m] |
l2 | Mean Length l2 of core [m] |
a | Height of core [m] |
b | Width of core [m] |
Material | |
mat | Parameter set of ferromagnetic Hysteresis |
Initialization | |
MagRelStart | Initial magnetization of Core (-1..1) |
MagRelFixed | Fixed |
HStart | Initial magnetic field strength of Core [A/m] |
HFixed | Fixed |
I1Start | Initial primary current through winding [A] |
I1Fixed | Fixed |
Losses and heat | |
HeatPort | |
useHeatPort | = true, if HeatPort is enabled |
T | Fixed device temperature if useHeatPort = false [K] |
Eddy currents | |
EddyCurrents | Enable eddy currents |
sigma | Conductivity of core material [S/m] |
t | Thickness of lamination [m] |
Leakage | |
L_l1 | Length of leakage of primary Winding [m] |
A_l1 | Cross section of leakage of primary Winding [m2] |
mu_rel1 | Constant relative permeability of primary leakage (>0 required) |
L_l2 | Length of leakage of secondary Winding [m] |
A_l2 | Cross section of leakage of secondary Winding [m2] |
mu_rel2 | Constant relative permeability of secondary leakage (>0 required) |
Name | Description |
---|---|
n1 | Negative pin of primary winding |
p1 | Positive pin of primary winding |
n2 | Negative pin of secondary winding |
p2 | Positive pin of secondary winding |
heatPort |
Three-phase transformer in Yy configuration
Simple model of a three-phase transformer with primary and a secondary windings and a magnetic E-I shaped core. The core is modeled with GenericHystTellinenEverett flux tube elements. Thus, this model considers static and dynamic hysteresis as well as initial flux.
Extends from Interfaces.ConditionalHeatPort (Partial model to include a conditional HeatPort in order to describe the power loss via a thermal network).
Name | Description |
---|---|
Electrical | |
Primary winding | |
N1 | Primary turns |
L1 | Mean primary turn length [m] |
d1 | Wire diameter of primary turns [m] |
rho1 | Resistivity of primary winding (at 20degC) [Ohm.m] |
alpha1 | Temperature coefficient of primary turns [1/K] |
Secondary winding | |
N2 | Secondary turns |
L2 | Mean secondary turn length [m] |
d2 | Wire diameter of secondary turns [m] |
rho2 | Resistivity of secondary winding (at 20degC) [Ohm.m] |
alpha2 | Temperature coefficient of secondary turns [1/K] |
Core | |
Geometry | |
l1 | Mean length l1 of core [m] |
l2 | Mean length l2 of core [m] |
a | Height of core [m] |
b | Width of core [m] |
Material | |
mat | Core Material |
Initialization | |
MagRelStart[3] | Initial magnetization of Core (-1..1) |
MagRelFixed[3] | Fixed |
HStart[3] | Initial magnetic field strength of Core [A/m] |
HFixed[3] | Fixed |
I1Start[3] | Initial current of primary Windings [A] |
I1Fixed[3] | Fixed |
I2Start[3] | Initial current of secondary Windings [A] |
I2Fixed[3] | Fixed |
Losses and heat | |
HeatPort | |
useHeatPort | = true, if HeatPort is enabled |
T | Fixed device temperature if useHeatPort = false [K] |
Eddy currents | |
EddyCurrents | Enable eddy currents |
sigma | Conductivity of core material [S/m] |
t | Thickness of lamination [m] |
Leakage | |
L_l1 | Length of leakage of primary Winding [m] |
A_l1 | Cross section of leakage of primary Winding [m2] |
mu_rel1 | Constant relative permeability of primary leakage (>0 required) |
L_l2 | Cross section of leakage of secondary Winding [m] |
A_l2 | Length of leakage of secondary Winding [m2] |
mu_rel2 | Constant relative permeability of secondary leakage (>0 required) |
Name | Description |
---|---|
heatPort | |
p1 | Primary winding 1 |
p2 | Primary winding 2 |
p3 | Primary winding 3 |
n1 | Secondary winding 1 |
n2 | Secondary winding 2 |
n3 | Secondary winding 3 |
starPoint2 | Star point of secondary windings |
starPoint1 | Star point of primary windings |