Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors

Sensors to measure variables in magnetic networks

Information

For analysis of magnetic networks, only magnetic potential differences and magnetic flux are variables of interest. For that reason, a magnetic potential sensor is not provided.

Extends from Modelica.Icons.SensorsPackage (Icon for packages containing sensors).

Package Content

Name Description
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.ReferenceSensor ReferenceSensor Sensor of reference angle gamma
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.FrequencySensor FrequencySensor Frequency sensor
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialSensor MagneticPotentialSensor Potential sensor
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialDifferenceSensor MagneticPotentialDifferenceSensor Sensor to measure magnetic potential difference
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticFluxSensor MagneticFluxSensor Sensor to measure magnetic flux
Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.Transient Transient Transient fundamental wave sensors

Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.ReferenceSensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.ReferenceSensor

Sensor of reference angle gamma

Information

This sensor determines the reference angle of the connected quasi-static magnetic system. The integral of the angular frequency of the quasi-static magnetic system is equal to the reference angle.

Extends from FluxTubes.Interfaces.AbsoluteSensor (Partial potential sensor).

Connectors

NameDescription
portQuasi-static magnetic port
yReference angle [rad]

Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.FrequencySensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.FrequencySensor

Frequency sensor

Information

This sensor can be used to measure the frequency of the reference system. The integral of the angular frequency of the quasi-static magnetic system is equal to the reference angle.

Extends from FluxTubes.Interfaces.AbsoluteSensor (Partial potential sensor).

Connectors

NameDescription
portQuasi-static magnetic port
y[Hz]

Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialSensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialSensor

Potential sensor

Information

This sensor can be used to measure the complex magnetic potential V_m in a quasi-static magnetic system.

Extends from FluxTubes.Interfaces.AbsoluteSensor (Partial potential sensor).

Connectors

NameDescription
portQuasi-static magnetic port
y 

Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialDifferenceSensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticPotentialDifferenceSensor

Sensor to measure magnetic potential difference

Information

This sensor can be used to measure the complex magnetic potential difference V_m in a quasi-static magnetic system.

Extends from FluxTubes.Interfaces.RelativeSensor (Partial magnetic voltage or flux sensor).

Connectors

NameDescription
port_pPositive quasi-static magnetic port
port_nNegative quasi-static magnetic port
y 

Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticFluxSensor Modelica.Magnetic.QuasiStatic.FluxTubes.Sensors.MagneticFluxSensor

Sensor to measure magnetic flux

Information

This sensor can be used to measure the complex magnetic flux Phi of a quasi-static magnetic system.

Extends from FluxTubes.Interfaces.RelativeSensor (Partial magnetic voltage or flux sensor).

Connectors

NameDescription
port_pPositive quasi-static magnetic port
port_nNegative quasi-static magnetic port
y 
Automatically generated Thu Oct 1 16:07:51 2020.