.Modelica.Mechanics.MultiBody.Sensors.Internal.BasicAbsoluteAngularVelocity

Information

This basic sensor is aimed to be used within advanced sensors where the absolute angular velocity of frame_a should be determined. This vector is provided at the output signal connector w.

Via parameter resolveInFrame it is defined, in which frame the angular velocity is resolved:

resolveInFrame =
Types.ResolveInFrameA.
Meaning
world Resolve vector in world frame
frame_a Resolve vector in frame_a
frame_resolve Resolve vector in frame_resolve

In this basic sensor model, the connector frame_resolve is always enabled and must be connected. If resolveInFrame = Types.ResolveInFrameA.frame_resolve, the vector w is resolved in the frame to which frame_resolve is connected.

Example

If resolveInFrame = Types.ResolveInFrameA.frame_a, the output vector is computed as:

w = MultiBody.Frames.angularVelocity2(frame_a.R);

Generated at 2020-06-05T21:39:08Z by OpenModelica 1.16.0~dev-442-g2e5bc9f