IMC_InverterTest example: InductionMachineSquirrelCage with inverter |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
An ideal frequency inverter is modeled by using a VfController and a three-phase SignalVoltage.
Frequency is raised by a ramp, causing the induction machine with squirrel cage to start,
and accelerating inertias.
At time tStep a load step is applied.
Simulate for 1.5 seconds and plot (versus time):
Default machine parameters are used.
VNominal |
Value: 100 Type: Voltage (V) Description: Nominal RMS voltage per phase |
---|---|
fNominal |
Value: 50 Type: Frequency (Hz) Description: Nominal frequency |
f |
Value: 50 Type: Frequency (Hz) Description: Actual frequency |
tRamp |
Value: 1 Type: Time (s) Description: Frequency ramp |
TLoad |
Value: 161.4 Type: Torque (N·m) Description: Nominal load torque |
tStep |
Value: 1.2 Type: Time (s) Description: Time of load torque step |
JLoad |
Value: 0.29 Type: Inertia (kg·m²) Description: Load's moment of inertia |
aimcData |
Value: Type: IM_SquirrelCageData Description: Induction machine data |
aimc |
Type: IM_SquirrelCage |
|
---|---|---|
currentQuasiRMSSensor |
Type: CurrentQuasiRMSSensor |
|
ramp |
Type: Ramp |
|
vfController |
Type: VfController |
|
signalVoltage |
Type: SignalVoltage |
|
star |
Type: Star |
|
ground |
Type: Ground |
|
loadInertia |
Type: Inertia |
|
loadTorqueStep |
Type: TorqueStep |
|
terminalBox |
Type: TerminalBox |
|
aimcData |
Type: IM_SquirrelCageData Description: Induction machine data |