IMC_YDarcTest example: InductionMachineSquirrelCage Y-D |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Same example as IMC_YD, but with a time delay between Y off and D on.
Note that a switchYDwithArc is used to avoid unphysical voltage peaks when opening Y connection.
Default machine parameters are used.
VNominal |
Value: 100 Type: Voltage (V) Description: Nominal RMS voltage per phase |
---|---|
fNominal |
Value: 50 Type: Frequency (Hz) Description: Nominal frequency |
RLine |
Value: 0.0001 Type: Resistance (Ω) Description: Line resistance |
LLine |
Value: 0.0001 / (2 * pi * fNominal) Type: Inductance (H) Description: Line inductance |
tStart1 |
Value: 0.1 Type: Time (s) Description: Start time |
tStart2 |
Value: 2.0 Type: Time (s) Description: Start time from Y to D |
TLoad |
Value: 161.4 Type: Torque (N·m) Description: Nominal load torque |
wLoad |
Value: 1440.45 * 2 * Modelica.Constants.pi / 60 Type: AngularVelocity (rad/s) Description: Nominal load speed |
JLoad |
Value: 0.29 Type: Inertia (kg·m²) Description: Load's moment of inertia |
aimcData |
Value: Type: IM_SquirrelCageData Description: Induction machine data |
aimc |
Type: IM_SquirrelCage |
|
---|---|---|
currentQuasiRMSSensor |
Type: CurrentQuasiRMSSensor |
|
sineVoltage |
Type: SineVoltage |
|
star |
Type: Star |
|
ground |
Type: Ground |
|
booleanStep |
Type: BooleanStep[m] |
|
idealCloser |
Type: IdealClosingSwitch |
|
switchYDwithArc |
Type: SwitchYDwithArc |
|
booleanStepYD |
Type: BooleanStep[m] |
|
loadInertia |
Type: Inertia |
|
quadraticLoadTorque | ||
aimcData |
Type: IM_SquirrelCageData Description: Induction machine data |
|
resistor |
Type: Resistor |
|
inductor |
Type: Inductor |