TransformerYYTest example with polyphase components |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Test example with polyphase components:
Star-connected voltage source feeds via a Y-Y-transformer with internal impedance (RT, LT) a load resistor RT.
Using f=5 Hz LT=3mH defines nominal voltage drop of approximately 10 %.
Simulate for 1 second (2 periods) and compare voltages and currents of source, transformer and load.
m |
Value: 3 Type: Integer Description: Number of phases |
---|---|
V |
Value: 1 Type: Voltage (V) Description: Amplitude of Star-Voltage |
f |
Value: 5 Type: Frequency (Hz) Description: Frequency |
Lm |
Value: 1 Type: Inductance (H) Description: Transformer main inductance |
LT |
Value: 0.003 Type: Inductance (H) Description: Transformer stray inductance |
RT |
Value: 0.05 Type: Resistance (Ω) Description: Transformer resistance |
RL |
Value: 1 Type: Resistance (Ω) Description: Load Resistance |
nT |
Value: 1 Type: Real Description: Transformer ratio |