ThyristorCenterTap2Pulse_RLV

Two pulse thyristor rectifier with center tap and R-L load and voltage

Diagram

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

This example shows a controlled center tap two pulse rectifier with R-L load including DC voltage source. The additional DC voltage source in this example enables negative average load voltages.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Parameters (6)

Vrms

Value: 110

Type: Voltage (V)

Description: RMS supply voltage

f

Value: 50

Type: Frequency (Hz)

Description: Frequency

constantFiringAngle

Value: 30 * pi / 180

Type: Angle (rad)

Description: Firing angle

R

Value: 20

Type: Resistance (Ω)

Description: Load resistance

L

Value: 1

Type: Inductance (H)

Description: Load resistance

VDC

Value: -120

Type: Voltage (V)

Description: DC load offset voltage

Components (13)

ground

Type: Ground

sinevoltage_n

Type: SineVoltage

sinevoltage_p

Type: SineVoltage

rectifier

Type: ThyristorCenterTap2Pulse

voltagesensor

Type: VoltageSensor

meanVoltage

Type: Mean

rootMeanSquareVoltage

Type: RootMeanSquare

currentSensor

Type: CurrentSensor

meanCurrent

Type: Mean

pulse2

Type: VoltageBridge2Pulse

resistor

Type: Resistor

inductor

Type: Inductor

constantVoltage

Type: ConstantVoltage