ThyristorCenterTap2Pulse_RLV_CharacteristicCharacteristic of two pulse thyristor rectifier with center tap and R-L load and voltage |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
This example shows a controlled center tap two pulse rectifier with R-L load including DC voltage source. The additional DC voltage source in this example enables negative average load voltages.
Plot average voltage meanVoltage.v
versus firingAngle pulse2.firingAngle
to see control characteristic of this type of rectifier with R-L load including active voltage.
Vrms |
Value: 110 Type: Voltage (V) Description: RMS supply voltage |
---|---|
f |
Value: 50 Type: Frequency (Hz) Description: Frequency |
R |
Value: 20 Type: Resistance (Ω) Description: Load resistance |
L |
Value: 1 Type: Inductance (H) Description: Load resistance |
VDC |
Value: -120 Type: Voltage (V) Description: DC load offset voltage |
ground |
Type: Ground |
|
---|---|---|
sinevoltage_n |
Type: SineVoltage |
|
sinevoltage_p |
Type: SineVoltage |
|
rectifier |
Type: ThyristorCenterTap2Pulse |
|
voltagesensor |
Type: VoltageSensor |
|
meanVoltage |
Type: Mean |
|
rootMeanSquareVoltage |
Type: RootMeanSquare |
|
currentSensor |
Type: CurrentSensor |
|
meanCurrent |
Type: Mean |
|
pulse2 |
Type: VoltageBridge2Pulse |
|
resistor |
Type: Resistor |
|
inductor |
Type: Inductor |
|
constantVoltage |
Type: ConstantVoltage |
|
ramp |
Type: Ramp |