ThyristorCenterTapmPulse_R

2*m pulse thyristor rectifier with center tap and resistive load

Diagram

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

This example shows a controlled m pulse center tap rectifier with resistive load, where m is the number of phases.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Parameters (5)

m

Value: 3

Type: Integer

Description: Number of phases

Vrms

Value: 110

Type: Voltage (V)

Description: RMS supply voltage

f

Value: 50

Type: Frequency (Hz)

Description: Frequency

constantFiringAngle

Value: 30 * pi / 180

Type: Angle (rad)

Description: Firing angle

R

Value: 20

Type: Resistance (Ω)

Description: Load resistance

Components (11)

ground

Type: Ground

star

Type: Star

sineVoltage_p

Type: SineVoltage

rectifier

Type: ThyristorCenterTapmPulse

voltagesensor

Type: VoltageSensor

meanVoltage

Type: Mean

rootMeanSquareVoltage

Type: RootMeanSquare

currentSensor

Type: CurrentSensor

meanCurrent

Type: Mean

pulsem

Type: VoltageBridge2mPulse

resistor

Type: Resistor